B D ALWS

When the system is set and (for example) an intruder violates a zone, then
the system waits for the programmed Bell Delay before sounding the Bell.
The system then sounds the bell for the programmed Bell Time. If someone
enters through the entry route during the Bell Delay the system does not
give entry tones.

B D OVER

The system starts the Bell Delay if an intruder violates a zone while the
system is set. However, if someone enters through the entry/exit door during
the Bell Delay then the end station immediately starts the keypad sounders
and the bell. This provides a warning that there is an intruder on the
premises. Note that the system also starts the bell if it detects a line failure
from the communicator during the Bell Delay.

61-INST CODE

This menu allows you to program the Installer's access code.
Note: Use the number keys to enter the access code.

62-PA RESPONSE

When a PA zone is activated, or a user presses keys 1 and 3 on a keypad,
you can program the system to respond in one of the following ways:
PAAUDIBL
The system activates all audible and visual warning devices,
and signalling if fitted. When a user enters a valid access
code the LCD keypad shows the PA zone.
PASILENT
The system activates signalling only. When a user enters a
valid access code the LCD keypad shows the PA zone.
PAHIDDEN
The system activates signalling and logs the event. The LCD
display remains unchanged, showing only the time and date.
Caution:
Do not program Silent Alarm unless a communicator is
fitted and operational. If the system specification requires
'Silent PA' and the communicator is fitted but awaiting BT
connection, temporarily program PA as audible.
Note: Use the C and D keys to select the appropriate response.

63-LF RESPONSE

This menu lets you program the system to respond with either audible,
silent, or tamper alarms when a plug-on communicator detects a fault on an
attached telephone line. The exact response depends on whether all Levels
are set, or one or more Levels unset, as follows:
496234
5. Programming Reference