Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point screws.
Verify gas pressures with the replace lit and at the highest setting.
1. Remove door (Fig. 25) and locate the valve as seen in Figure 26
2. Locate the inlet and outlet test points on the valve which can be seen in Figure 36. After
locating the ports loosen the screws within the ports using a at-tip screwdriver.
3. Attach pressure gauge to the test ports
4. Turn gas supply back on and test pressures.
5. After testing is nished turn off gas supply, remove the pressure gauges and retighten the
screws in the test points.
BRSL.BODYB
140515-44
BDFD.BODYB
Gas Pressure Testing Procedure
Figure 25: Valve Location
the valve in Figure 26.
Battery Box
Figure 26: Valve
21
INFORMATION
Pilot Adjustment
The pilot flame level can be adjusted
by turning the adjustment screw,
using a flat-tip screwdriver, seen on
5055.633-B
INSTALLER