TESTED and LISTED to CAN/ULC S610-M87 AND UL 127 Meets the Environmental Protection Agency's July 1990 Particulate Emission Standards MODEL: PACIFIC FP30 ZERO CLEARANCE WOOD FIREPLACE 190913-28 PACIFIC FP30 5055.5152...
Appendix A ................. 24 may result in property damage, bodily Troubleshooting ................... 24 injury, or even death. Understanding & Operating Your Pacifi c Energy Stove ......25 Replacement Parts ................26 Label Location ..................27 Label ....................27 PACIFIC FP30 190913-28...
(see Floor Protector section on page 18 for Floor Protec- Periodically inspect seals and replace if necessary. tion dimensions) 7. DOOR GLASS - Replacement glass can be obtained from your dealer. Use 11 3/8" x 21 5/8" x 5 mm ceramic glass only. PACIFIC FP30 190913-28...
- Replace if the baffle has permanent warping greater than this or has cracking or breakage. - Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty PACIFIC FP30 190913-28...
In the event of a Chimney Fire 1. Prepare to evacuate to ensure everyone's safety. Have a well understood plan of action for evacuation. Have a place outside where everyone is to meet. 2. Close air inlet on stove. PACIFIC FP30 190913-28...
3. Use wood of different shape, diameter and length (up to Your PACIFIC ENERGY heater is designed for maximum 20"). Load your wood endwise and try to place the logs overall efficiency at a moderate fi ring rate. Over fi ring is so that the air can fl ow between them.
It is also recommended that the blower be wired to a wall switch or dimmer switch for manual control. If the blower should ever need to be replaced, power to the blower can be shut off at the switch during replacement. PACIFIC FP30 190913-28...
(230 mm x 115 mm x 32 mm) 5096.99 9” X 3 1/2” X 1 1/4” (102 mm x 115 mm x 32 mm) 3245.501 7 1/4” X 4 1/2” X 1 1/4” (184 mm x 115 mm x 32 mm) 245.001 PACIFIC FP30 190913-28...
Penetrate the highest part of the roof. • Be installed as far as possible from roof offsets, trees or any other obstructions that may cause wind turbulence or back drafts in the chimney. • The least amount of offsets (elbows) possible. PACIFIC FP30 190913-28...
Using the screws provided (1), attach the framing kit legs(4) to the bottom stud (2). • Next, attach each center support(3) to the bottom stud(2) and then attach the top stud(2) to the center supports(3). FIG. #9 PACIFIC FP30 190913-28...
Minimum Clearances to Combustibles FIG. #10 PACIFIC FP30 190913-28...
Page 15
Non-combustible fl oor protector * 4" diameter combustion outside air inlet. One on either side of unit. The combustion air inlets can be rotated to draw air from the rear of the unit if desired. PACIFIC FP30 190913-28...
Cover the insulation with drywall panels need to install an Anchor Plate spacer. Part #FP30.7757) around the fi replace. It is not required to install a chase outlet but doing so can provide extra heat into the room. PACIFIC FP30 190913-28...
Maximum chimney height supported by fireplace. 25’ (7.62m) Minimum depth of non-combustible hearth extension: from the front of the 18” (457mm) fireplace. Minimum width of floor protection from side of door opening(in U.S.A.) and from side of unit(in Canada). PACIFIC FP30 190913-28...
1. Using a pair of tin snips, cut away the square section block- ing the heat duct openings and cut out insulation(Fig.#19). 2. Attach the heat duct adapter/s with the screws provided in the FP30.GVKIT (Fig. #19). PACIFIC FP30 190913-28...
Page 21
3/4” thick(Max. 4"), connect additional room air to the 6" Gravity Vent air inlet on the left side of the fi replace casing using the adapter provided(Fig. #22). FLOOR FIG. #22 FIG. #20 WALL OUTLET 11 1/4” 9 3/4” PACIFIC FP30 190913-28...
Tape and mud the joints as per the board manufacturers recommendations. FIG. #24 NON-COMBUSTIBLE CEMENT BOARD 29” REQUIRED DECORATIVE NON-COMBUSTIBLE FACING MAXIMUM 4” THICK 30in2 (194cm2) CHASE AIR INLET 1 1/2” 60.00 ALTERNATE LOCATION FOR CHASE AIR INLET PACIFIC FP30 190913-28...
1. Combustion air supply blocked - Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, consult Dealer PACIFIC FP30 190913-28...
*19 ..Gravity Vent Adapter ....... FP30.9128 *20 ..Anchor plate spacer ....... FP30.7757 All parts may be ordered from your nearest Pacifi c Energy NOT SHOWN dealer. Contact Pacifi c Energy for the location of the dealer nearest you. PACIFIC FP30 190913-28...
• BLOWER ELECTRICAL RATING 115V, 60HZ, 1.0AMP • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS. • DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.
Page 28
PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Phone: 250-748-1184 Web site: http://www.pacifi cenergy.net Printed in Canada...