Pacific energy BRISTOL Installation And Operating Instructions Manual
Pacific energy BRISTOL Installation And Operating Instructions Manual

Pacific energy BRISTOL Installation And Operating Instructions Manual

Direct vent gas inserts

Advertisement

Quick Links

INSTALLER:
Leave this manual with the appliance.
CONSUMER:
Retain this manual for future reference.
WARNING: If the information in these
instructions is not followed exactly a re
or explosion may result causing property
damage, personal injury or death.
FOR YOUR SAFETY
Do not store or use gasoline or other
ammable vapours and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical Switch.
• Do not use any phone in your building.
• Immediately call your gas supplier
from a neighbour's phone. Follow the gas
supplier's instructions.
• If you cannot reach your gas supplier
call the re department.
Installation and service must be performed
by a quali ed installer, service agency or
the gas supplier.
This appliance may be installed in
an aftermarket permanently located,
manufactured home (USA only) or mobile
home, where not prohibited by local codes.
This appliance is only for use with the type of
gas indicated on the rating plate. This appliance
is not convertible for use with other gases
unless a certi ed kit is used.
This appliance is suitable for installation in a
bedroom or bed sitting room.
140515-44
BRISTOL & BEDFORD
INSTALLATION AND

OPERATING INSTRUCTIONS

MODEL: BRISTOL / BEDFORD
SERIES: B
DIRECT VENT GAS INSERTS
BRSL.BODYB
BDFD.BODYB
5055.633-B

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy BRISTOL

  • Page 1: Operating Instructions

    This appliance is not convertible for use with other gases unless a certi ed kit is used. MODEL: BRISTOL / BEDFORD This appliance is suitable for installation in a SERIES: B bedroom or bed sitting room.
  • Page 2: Note For Massachusetts

    Important Note for the Commonwealth of Massachusetts: From Massachusetts Rules and Regulations 248 CMR 5.08: (a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above nished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satis ed.
  • Page 3: Table Of Contents

    Replacement Parts ......... 38 Clearances to Combustibles ......17 Wiring Diagram ..........39 Venting ............. 18 Bristol Rating Label ......... 40 Plumbing and Electrical ........19 Bedford Rating Label ........41 Gas Supply ............20 Gas Pressure Check / Output / Efficiency ..20 BRSL.BODYB...
  • Page 4: Owners Information

    Caution INFORMATION FOR YOUR SAFETY - Do not install or operate your Pacific Energy appliance without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Pacific Energy Warranty and may prove hazardous.
  • Page 5: Safety

    OWNER’S Safety INFORMATION • Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies. • Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. •...
  • Page 6: First Fire

    OWNER’S INFORMATION Congratulations on your purchase of a Pacific Energy Gas Appliance. Your fireplace has been professionally installed by: Dealer name: _______________________________ Phone Number:_____________________________ If you discover any problems with your gas appliance contact your dealer immediately to have the unit repaired.
  • Page 7: Remote Control Operation

    OWNER’S Remote Control Operation INFORMATION System Description The Proflame2 Remote Control System consists of two elements: 1. Proflame2 Transmitter. 2. Proflame2 Integrated Fireplace Control (IFC) board and a wiring harness to connect the IFC to the gas valve and stepper motor. Transmitter (Remote Control with LCD Display) The Pro ame2 Transmitter uses a streamline design with a simple button layout and informative LCD display (Fig.
  • Page 8: Ifc Module

    OWNER’S INFORMATION IFC Module The Pro ame2 Integrated Fireplace Control (IFC) module (Fig. 3) is a device that allows automatic ignition and pilot ame supervision, and commands the functions of the hearth Heater. It’s con gured to control the ON/OFF main burner operation, giving the choice of both IPI (intermittent pilot ignition), and CPI (continuous pilot ignition) modes.
  • Page 9: Bdfd.bodyb

    OWNER’S INFORMATION Temperature indication Display With the system in the “OFF” position, press the Thermostat Key and the Mode Key at the same time. Look at the LCD screen on the transmitter to verify that a C or F is visible to the right of the Room Temperature display.
  • Page 10: Bdfd.bodyb

    OWNER’S INFORMATION Remote Flame Control The Pro ame has six (6) ame levels. With the system on, and the ame level at the maximum in the appliance, pressing the down arrow key once will reduce the ame height by one step until the ame is turned off.
  • Page 11 OWNER’S INFORMATION Comfort Fan Speed Control If the Heater is equipped with a hot air circulating fan, the speed of the fan can be con- trolled by the Pro ame2 System. The fan speed can be adjusted through six (6) speeds. To activate this function use the Mode Key (Fig.
  • Page 12: Warnings And Cautions

    OWNER’S INFORMATION Low Battery Power Detection Transmitter The life span of the remote control batteries depends on various factors: quality of the batteries used, the number of ignitions of the Heater, the number of changes to the room thermostat set point, etc.
  • Page 13: Maintenance

    OWNER’S Maintenance INFORMATION Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the replace and its venting should be inspected at least once a year by a quali ed service person. Glass Door: Warning: Do not operate replace with glass door removed, cracked or broken.
  • Page 14: Lighting Instructions

    OWNER’S Lighting Instructions INFORMATION BRSL.BODYB 140515-44 5055.633-B BDFD.BODYB...
  • Page 15: Installer Information

    25.1/8” 2 1/8” 15 7/8” 19 7/8” 18 3/4” 16 34” 20” 22 5/8” 12 5/8” 16 3/8” Figure 16: Bristol Dimensions ‘ Bedford: 17 3/8” 6 1/4” 33 1/8” 23 1/2” 2 1/8” 22 7/8” 21 7/8” 17 5/8”...
  • Page 16: Existing Fireplace Preparation

    INSTALLER Existing Fireplace Preparation INFORMATION The Bristol and Bedford Gas inserts are certi ed to be installed into pre-existing approved re place cavities. The minimum cavity requirements are listed in Figure 18 below. Dimension Bristol Bedford 16-7/8” 16-7/8” 21” 23”...
  • Page 17: Clearances To Combustibles

    Clearances to Combustibles INSTALLER INFORMATION * MANTEL CLEARANCE FLAT SURROUND BEDFORD BRISTOL LOUVERE CLEAN BROW LOUVERE CLEAN BROW 37” 27” 30” 45” 36” 37” 36” 27” 29” 44” 36” 36.5” * MANTEL CLEARANCE BEVELLED 35” 27” 28” 43” 36” 36”...
  • Page 18: Venting

    Figure 22: High Wind (Bristol 46DVA-CL33) intake vent. Vent Terminal (Bedford 46DVA-CL34) Prairie Co-Linear Kit Bristol has both 3 inch dia. (Bristol 46DVA-CL33P) exhaust and intake vents. (Bedford 46DVA-CL34P) Only certified venting systems or components may be installed with this fireplace.
  • Page 19: Plumbing And Electrical

    INSTALLER Plumbing and Electrical INFORMATION Figure 24: Gas and Electrical Connections Note: Installation requires that an electrical outlet be installed into existing fireplace cavity before insert is installed. To make the required electrical and gas connections start by positioning the gas insert within the existing fireplace.
  • Page 20: Gas Supply

    WARNING: The gas tray including gasket must be reinstalled after conversion/installation or servicing has been completed. Gas Pressure Check / Output / Efficiency Please refer to following page for gas pressure testing procedure. Gas pressure requirements Bristol Gas Orifice Output AFUE Input Pressure Natural Gas Propane 1.98mm...
  • Page 21: Gas Pressure Testing Procedure

    INSTALLER Gas Pressure Testing Procedure INFORMATION Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point screws. Verify gas pressures with the replace lit and at the highest setting. 1. Remove door (Fig. 25) and locate the valve as seen in Figure 26 2.
  • Page 22: Propane Conversion

    INSTALLER Propane Conversion INFORMATION Before starting the conversion make sure to shut off the gas supply to the unit and allow replace to cool to room temperature. o convert the gas replace insert from natural gas to propane the (GASC.LPKIT) kit is required. This kit comes with new pilot and burner ori ces as well as a new pressure modulator for the valve.
  • Page 23: Adjustable Leveling Bolts

    INSTALLER Adjustable Leveling Bolts INFORMATION Adjustable leveling bolts This replace comes with two leveling bolts used to adjust the angle of the front of the replace relative to the wall in which it’s installed. The bolts are not pre-installed and can be found in a separate plastic bag.
  • Page 24: Surround Installation Instructions

    INSTALLER Surround Installation Instructions INFORMATION Surround Installation Figure 32: Door Figure 33: Surround hand lintel tab The surround cover (Fig.32) attaches to the lintel once the decorative backing plate has been installed. The surround easily ts into place by connecting all four of its hooks to the lintels four tabs (Fig.33). Figure 35: Surround in place (backing not shown) Figure 34: Top of surround fitting inside the baffle during installation...
  • Page 25 INSTALLER INFORMATION BRISTOL FRONTS BEDFORD FRONTS 32” 24” 23 1/2” 20 1/2” BRCA.18LFBKB - LOUVERED BLACK BDCD.30LFBKB - LOUVERED BLACK BRCA.18LFGYB - LOUVERED GREY BDCD.30LFGYB - LOUVERED GREY 24” 32” 20 1/2” 231/2” BRCA.18CFBKB - CONTOURED BLACK BDCD.30CFBKB - CONTOURED BLACK BRCA.18CFGYB - CONTOURED GREY BDCD.30CFGYB - CONTOURED GREY Figure 36: Fronts Sales Codes BRSL.BODYB 140515-44 5055.633-B BDFD.BODYB...
  • Page 26 INSTALLER INFORMATION BEDFORD SURROUNDS BRISTOL SURROUNDS 40” 32” 27 1/2” 24 7/16” BRSL.18FSBBKA - REGULAR BACKING PLATE - BLACK BDFD.30FSBBKA - REGULAR BACKING PLATE - BLACK BDFD.30FSBGYA - REGULAR BACKING PLATE - GREY BRSL..18FSBGYA - REGULAR BACKING PLATE - GREY 40” 32” 29 9/16” 24 7/16” BRSL.18BSBBKA - BEVELED BACKING PLATE - BLACK BDFD.30BSBBKA - BEVELED BACKING PLATE - BLACK BRSL.18SBGYA - BEVELED BACKING PLATE - GREY BDFD.30BSBGYA - BEVELED BACKING PLATE - GREY 40” 48” 30 9/16” 27 9/16” BDFD.30OSFSBBKA - OVERSIZE BACKING PLATE - BLACK BRSL.18OSFSBBKA - OVERSIZE BACKING PLATE - BLACK BDFD.30OSFSBGTYA - OVERSIZE BACKING PLATE - GREY BRSL.18OSFSBGYA - OVERSIZE BACKING PLATE - GREY Figure 37: Surround Dimensions BRSL.BODYB...
  • Page 27: Battery Holder

    INSTALLER Battery Holder INFORMATION A new battery holder bracket replaces the older one in the series A replaces. The older one (Fig. 38) was riveted into place while the new series B bracket (Fig. 39) is screwed into place. Figure 38: Older riveted bracket. Figure 39: New bracket.
  • Page 28: Fan Removal /Installation

    INSTALLER Fan Removal / Installation INFORMATION Make sure that the gas and electrical supply is shut off. Locate and remove the two 3/8” bolts securing the bottom of door as seen in Figure 41 Figure 41 2. Tilt the bottom of the door away from the appliance and lift the door off. Media Removal Removal ( gures 42 &...
  • Page 29 INSTALLER INFORMATION Removing the Burner and Burner tray. 1. Remove the screw holding the burner to the burner tray (Figure 44). 2. Remove two screws from the upper baffle and remove (Fig. 45) Figure 44 Figure45 Figure 46 3. Remove two screws from the burner plate (Fig. 46) and remove. 4.
  • Page 30 INSTALLER INFORMATION Figure 50 Figure 51 5. Remove two screws which hold the back ledge (Fig.50) in place and remove. 6. Remove the approximately 25 screws hold the base plate (Fig. 51) to the frame of the rebox. 7. Gently remove the base plate (Fig. 52) and set aside to the right hand side of the rebox. There is no need to disconnect any of the electrical or gas ttings.
  • Page 31 INSTALLER INFORMATION 8. The fan is located inside the opening and toward the rear of the rebox. A 3/8” nut holds the fan assembly onto a threaded post. Remove the nut and gently extract the fan assembly from the re box (Fig.
  • Page 32: Panel Installation/Removal

    INSTALLER Panel Installation / Removal INFORMATION NOTE: Air De ector from burner kit needs to be installed before panels. See Burner Kit Installation. Installation 1. Insert back panel so that it is sitting on ledge at the back of the rebox as shown in Figure 57. Figure 56: Panel Set 2.
  • Page 33: Burner Installation/Removal

    INSTALLER INFORMATION Air De ector Installation / Removal Installation Position the air de ector in the replace as seen in Figure 60 and secure with two screws using a screw- driver. Removal Remove the two screws seen in Figure 60 using a screwdriver, and remove the air de ector from replace.
  • Page 34: Log Set Installation/Removal

    INSTALLER Log Set Installation / Removal INFORMATION Installation 1. Position rear log against the back rebox as seen in Figure 65. 2. Position front log just behind the front burner tube as seen in Figure 66. 3. Position log 3 with the thin end of the log resting on top of the right end of the front log as seen in Figure 67.
  • Page 35: Rustic Log Set Installation/Removal

    INSTALLER Rustic Log Set Installation / Removal INFORMATION Installation 1. Position rear logs #1 and #2 against the back box as seen in Figure 71. 2. Position front logs #3 and #4 between the front burner tubes as seen in Figure 72. 3.
  • Page 36: Glass Burner Kit Installation/Removal

    INSTALLER Glass Burner Installation / Removal INFORMATION Air De ector Installation / Removal Installation Position the air de ector in the replace as seen in Figure 77 and secure with two screws using a screwdriver. Removal Remove the two screws seen in Figure 77 using a screwdriver, and remove the air de ector from replace.
  • Page 37: Damper/Air Shutter

    INFORMATION The Bristol and Bedford replaces both come with an adjustable damper that can limit the ow of intake air. This damper is located behind the air de ector at the rear of the inner rebox. Sometimes on installations that involve vertical venting con gurations over 10 feet in height, the intake air tends to accelerate down the vent causing hectic ame action.
  • Page 38: Replacement Parts

    INSTALLER Replacement Parts INFORMATION Description Order Number 1. Bristol Regular Screen..........GBWY.SCRNA 2. Bedford Regular Screen..........GBNT.SCRNA 3. Complete Replacement Gas Tray......GASC.BRNTRAYA 4. Replacement Remote Control........GASC.CNTRLA Brnt Estt Blower ............BRET.BLOWB 6. Bdwy Estm Blower............BDEM.BLOWB Bristol Aesthetic Components Bedford Aesthetic Components BDFD.BODYB...
  • Page 39: Wiring Diagram

    INSTALLER Wiring Diagram INFORMATION Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing. Figure 82: Wiring diagrams BRSL.BODYB 140515-44 5055.633-B BDFD.BODYB...
  • Page 40: Bristol Rating Label

    INSTALLER Bristol Rating Label INFORMATION VENTED GAS FIREPLACE - NOT FOR USE LC- 211 WITH SOLID FUEL///FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE This Appliance is Equipped For Use With / ANSI Z21.88-2014 / CSA 2.33-2014 Vented Gas Fireplace Heaters Cet Appareil est Équipé...
  • Page 41: Bedford Rating Label

    FOR USE WITH GLASS DOORS CERTIFIED WITH THE APPLIANCE ONLY / POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIÉES AVEC L’APPAREIL Pacific Energy MINIMUM CLEARANCES TO COMBUSTIBLES / CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se déterminent Fireplace Products Ltd.
  • Page 42 INSTALLER INFORMATION BRSL.BODYB 140515-44 5055.633-B BDFD.BODYB...
  • Page 43 INSTALLER INFORMATION BRSL.BODYB 140515-44 5055.633-B BDFD.BODYB...
  • Page 44 © 2015 Copyright Paci c Energy Fireplace Products LTD. Reproduction, adaptation, or translation without prior written permission is prohibited except as allowed under the copyright laws. INSTALLER For technical support, please contact your retailer Web site: www. pacificenergy.net 2975 Allenby Rd., Duncan, BC V9l 6V8...