Gas Pressure Testing Procedure; Pilot Adjustment - Pacific energy BRISTOL Installation And Operating Instructions Manual

Table of Contents

Advertisement

Note: To test the gas pressure, turn off the gas supply to the appliance before loosening test point screws.
Verify gas pressures with the replace lit and at the highest setting.
1.
Remove door, See Figure 35 on page 23 and locate the valve as seen in Figure 26.
2.
Locate the inlet and outlet test points on the valve which can be seen in Figure 28 and Figure 29. After locating the
ports loosen the screws within the ports using a at-tip screwdriver.
3.
Attach pressure gauge to the test ports
4.
Turn gas supply back on and test pressures.
5.
After testing is nished turn off gas supply, remove the pressure gauges and retighten the screws in the test points.
Figure 28: Valve location.
The pilot ame level can be adjusted by turning the adjustment screw, using a at-tip screwdriver, seen on
the valve in Figure 29.
Figure 29: Valve.
BRSL.BODYB
050216-44
BDFD.BODYB

Gas Pressure Testing Procedure

Pilot Adjustment

Battery Holder
21
5055.633-B