TESTED and LISTED to CAN/ULC S610-M87 AND UL 127 Meets the Environmental Protection Agency's July 1990 Particulate Emission Standards MODEL: PACIFIC FP30 ZERO CLEARANCE WOOD FIREPLACE 060514-28 PACIFIC FP30 5055.5152...
Appendix A ................. 24 may result in property damage, bodily Troubleshooting ................... 24 injury, or even death. Understanding & Operating Your Pacifi c Energy Stove ......25 Replacement Parts ................26 Label Location ..................27 Label ....................27 PACIFIC FP30 060514-28...
Periodically inspect seals and replace if necessary. (see Floor Protector section on page 19 for Floor Protec- tion dimensions) 7. DOOR GLASS - Replacement glass can be obtained from your dealer. Use 11 3/8"9289mm) x 21 5/8"(549mm) x 5 mm ceramic glass only. PACIFIC FP30 060514-28...
- Replace if the baffle has permanent warping greater than this or has cracking or breakage. - Please contact your Dealer if you experience any of the damage listed above. Continuing to operate your stove with broken parts may accelerate damage to other parts and may void your warranty PACIFIC FP30 060514-28...
-Vibration of the chimney In the event of a Chimney Fire 1. Prepare to evacuate to ensure everyone's safety. Have a well understood plan of action for evacuation. Have a place outside where everyone is to meet. PACIFIC FP30 060514-28...
2. To refuel, adjust air control all the way to the left(High), Your PACIFIC ENERGY heater is designed for maximum and give the fi re time to brighten. Open the door slowly, overall efficiency at a moderate fi ring rate. Over fi ring is this will prevent back puffing.
It is also recommended that the blower be wired to a wall switch or dimmer switch for manual control. If the blower should ever need to be replaced, power to the blower can be shut off at the switch during replacement. PACIFIC FP30 060514-28...
(230 mm x 115 mm x 32 mm) 5096.99 9” X 3 1/2” X 1 1/4” (102 mm x 115 mm x 32 mm) 3245.501 7 1/4” X 4 1/2” X 1 1/4” (184 mm x 115 mm x 32 mm) 245.001 PACIFIC FP30 060514-28...
Penetrate the highest part of the roof. • Be installed as far as possible from roof offsets, trees or any other obstructions that may cause wind turbulence or back drafts in the chimney. • The least amount of offsets (elbows) possible. Clearances PACIFIC FP30 060514-28...
Using the screws provided (1), attach the framing kit legs(4) to the bottom stud (2). • Next, attach each center support(3) to the bottom stud(2) and then attach the top stud(2) to the center supports(3). FIG. #9 PACIFIC FP30 060514-28...
Page 15
One on either side of unit. The combustion air inlets can be relocated to draw air from the rear of the unit if desired. See page 18. Only one is required to be hooked up for to outside combustion air if desired. PACIFIC FP30 060514-28...
It is not required to install a chase outlet but doing so can provide extra heat into the room as well as ensure better cooling of the chase. NOTE: Chase inlet and optional outlet are intended to be in the same room as the fi replace. PACIFIC FP30 060514-28...
Maximum chimney height supported by fireplace. 25’ (7.62m) Minimum depth of non-combustible hearth extension: from the front of the 18” (457mm) fireplace. Minimum width of floor protection from side of door opening(in U.S.A.) and from side of unit(in Canada). PACIFIC FP30 060514-28...
1. Using a pair of tin snips, cut away the square section blocking the heat duct openings and cut out and remove insulation(Fig.#19). 2. Attach the heat duct adapter/s with the screws provided in the FP30.GVKIT (Fig. #19). PACIFIC FP30 060514-28...
Page 21
FIG. #20 WALL OUTLET 11 1/4” 286mm 9 3/4” 248mm GRAVITY HEAT DUCT AIR INLET. used only when two gravity vents and/or your facing material is more than 3/4”(19mm) thick(Max. 4"(102mm)), NOT RELATED TO CHASE AIR INLET PACIFIC FP30 060514-28...
NON-COMBUSTIBLE FACING MAXIMUM 4”(102mm) THICK 30in2 (194cm2) CHASE AIR INLET 1 1/2”(38mm) MINIMUM HEIGHT FROM FLOOR 18”(457mm) MAXIMUM HEIGHT FROM FLOOR 60.00” 1.5m ALTERNATE LOCATION FOR CHASE AIR INLET CAN ALSO BE ON OTHER SIDE OF CHASE PACIFIC FP30 060514-28...
1. Combustion air supply blocked - Check outside air supply for obstruction - Check that room air cover is removed 2. Draft too low - Chimney plugged or restricted, inspect and clean - Chimney oversized or otherwise unsuitable, consult Dealer PACIFIC FP30 060514-28...
*20 ..Anchor plate spacer(for use with ICC Chimney olny) ................FP30.7757 All parts may be ordered from your nearest Pacifi c Energy dealer. Contact Pacifi c Energy for the location of the dealer NOT SHOWN nearest you. PACIFIC FP30 060514-28...
• BLOWER ELECTRICAL RATING 115V, 60HZ, 1.0AMP • REPLACE GLASS ONLY WITH 5mm CERAMIC GLASS. • DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.
Page 28
PACIFIC ENERGY FIREPLACE PRODUCTS LTD. 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Phone: 250-748-1184 Web site: http://www.pacifi cenergy.net Printed in Canada...