Pacific energy Alderlea T5 Installation And Operating Instrictions

Pacific energy Alderlea T5 Installation And Operating Instrictions

Series: d classic insert fireplace

Advertisement

IMPORTANT:
THESE INSTRUCTIONS ARE TO
REMAIN WITH THE HOMEOWNER
SAVE THESE INSTRUCTIONS

SAFETY NOTICE

If this stove is not properly installed, a house
fi re may result. For your safety, follow the
installation instructions.
building or fi re officials about restrictions
and installation inspection requirements in
your area.
TESTED and LISTED
to ULC S628 / UL 1482
Meets the U.S. Environmental Protection
Agency's July 1990 Particulate Emission
Standards
180314-24
Alderlea T5
Classic Insert
Contact local
INSTALLATION
AND OPERATING
INSTRUCTIONS
MODEL: ALT5 INSERT
SERIES: D
PRODUCT CODE:
ALT5.CPINSBKA
ALT5.CPINSBNA
ALT5.CPINSB
SERIAL #
5055.2031

Advertisement

Table of Contents
loading

Summary of Contents for Pacific energy Alderlea T5

  • Page 1: Safety Notice

    THESE INSTRUCTIONS ARE TO REMAIN WITH THE HOMEOWNER SAVE THESE INSTRUCTIONS SERIAL # SAFETY NOTICE Alderlea T5 Classic Insert If this stove is not properly installed, a house fi re may result. For your safety, follow the installation instructions. Contact local...
  • Page 2: Table Of Contents

    Contents Safety ....................3 Clearances ..................3 Masonry or Factory Built Fireplace ..........3 Maintenance Checks................4 Dimensions ..................6 Installation ..................7 Fireplace Specifi cations ............. 7 Into a Masonry Fireplace ............7 Full Flue Liner (Required in Canada) Fig #2 ......8 Direct Flue Connection (Only permitted in USA) Fig #4 .....
  • Page 3: Safety

    Safety Clearances Please read this entire manual before installation Masonry or Factory Built Fireplace and use of this wood burning insert. Failure to follow The minimum required clearances to surrounding combustible these instructions could result in property damage, materials when installed into a masonry or factory built fi replace bodily injury or even death.
  • Page 4: Maintenance Checks

    Maintenance Checks Check the following parts for damage such as cracks, excessive corrosion, burned out sections and excessive warping: (See website for descriptions and more detail) Weekly: - Firebrick - Visual, for cracking. - Door Gasket - sagging, placement, damage. Monthly - Brick rail tabs and brick rails.
  • Page 5 Fireplace hearth requirements: (Measured without the insert) The non-combustible fi replace hearth must be raised 2” above an adjacent combustible fl oor and extend 16” in front and 8” beyond each side of the existing fi replace opening. A non-combustible hearth that extends a minimum 23-1/2” in front of the fi replace opening may be fl ush to an adjacent combustible fl oor.
  • Page 6: Dimensions

    Dimensions ALT5 INSERT & ALT5 CLASSIC INSERT WITH REGULAR SURROUND WITH OVERSIZED SURROUND 34 1/8" 30 3/8" 29 3/8" 33 1/8" 42 1/2" 42 1/2" 17 5/8" 9 1/2" 20 7/8" 21 1/2" 17 5/8" 10 5/8" 23 7/8" 28 3/8" 33 5/8"...
  • Page 7: Installation

    Installation Full Flue Liner Fig. # 2 (Required in Canada) Your Insert is designed to be installed into a masonry or factory-built, zero-clearance wood burning fi replace. The masonry fi replace must be built according to the requirements of the Standard of Chimneys, Fireplaces, Vents and Solid Fuel Burning appliances, N.F.P.A.
  • Page 8: Full Flue Liner (Required In Canada) Fig #2

    Full Flue Liner (Required in Canada) Fig #2 Into a Factory Built Fireplace Your Pacifi c Insert may be installed into a factory built fi replace This fi replace insert must be installed with a continuous liner with the following requirements: of 6”...
  • Page 9: Combustion Air

    Combustion Air Fig. # 6 Consult local building codes regarding combustion air supply. Intake or combustion air can be supplied to the Insert in one of two ways: 1) Outside air (O/A) supply: Remove cover from ash clean out in existing fi replace. Place a rodent screen in place of the cover.
  • Page 10: Surround Assembly And Installation

    Surround Assembly and Installation Fig. # 10 1) Remove crate and all plastic packaging. 2) Remove Top(A) and Shields(B). (Fig. #8) 3) Remove Surround Top and Sides from Packaging. 4) Remove the surround brackets from the stove(Fig. #9) and attach to the Surround sides as shown in Fig. #10. Use the bolts and washers in the mounting hardware kit found with the Surround Top.
  • Page 11: Fan Removal/Installation

    7) Install fan shield as shown in Fig. #13. Be sure to place the Fig. # 15 air inlet opening against the surround side. 8) Install the cast decorative top by tilting it at a slight angle, sliding it under the surround top, and settling it over the fan SLOT shields.
  • Page 12: Fan Speed Controller Relocation

    Fan Speed Controller Relocation 4) Loosen the two bolts that secure the ash lip to the fi rebox (Fig #22), carefully lift up the ash lip and remove from the fi rebox. The fan speed controller is factory installed under the ash lip on the right hand side.
  • Page 13 7) Remove the control assembly from the ashlip bracket on the 9) Reconnect the wires to the fans (Fig.28) and re-attach thermal right hand side. Flip it over and reattach on the left hand side snap switch (Fig.29). Refi t ash lip, sides and top. Ensure that of the ashlip (Fig #25).
  • Page 14: Operation

    Operation 1) Adjust air control to "H" (high) position (pushed to the far left) and open door. 2) Place crumpled newspaper in the centre of the heater and criss-cross with several pieces of dry kindling. Add a few Wood Selection small pieces of dry wood on top.
  • Page 15: Restarting After Extended Or Overnight Burns

    Restarting After Extended or Overnight Burns Blower 1) Open door and rake hot embers towards the front of the heater. Add a couple of dry, split logs on top of embers, close door. The Alderlea Insert comes equipped with twin variable speed 2) Adjust air control to “H”...
  • Page 16: Creosote

    Creosote In Case of a Chimney Fire 1. Prepare to evacuate to ensure everyone’s safety. Have a well understood plan of action for evacuation. Have a place Formation and Need for Removal outside where everyone is to meet. When wood is burned slowly, it produces tar and other organic 2.
  • Page 17: Maintenance

    Maintenance - Do not clean glass when hot - Do not use abrasive cleaners on glass 1. Burn wood only, dry and well seasoned. The denser or heavier 6. The area where boost combustion air enters the fi rebox must the wood when dry, the greater its heat value.
  • Page 18: Replacement Parts

    Replacement Parts (WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION) ITEM DESCRIPTION PART NO. ITEM DESCRIPTION PART NO. 1....Surround, Black Enamel....ALT5.SPBKA *8 ..Glass Clamp Set (4 pc.) ......4720.01 ....Surround, Majolica Brown Enamel ..ALT5.SPBNA *9 ..Replacement Glass (c/w Tape) ..5034.20806 ....O/S Surround, Black Enamel ..ALT5.SPBKOSA 10 ..Door Assy, Black Enamel ..
  • Page 19: Appendix A

    5 to particulates (smoke). 10 minutes more and Pacific Energy has then set the air control designed a system that to the desired position.
  • Page 20: Troubleshooting

    Troubleshooting Problem Cause Cure Excessive Creosote 1) Wood is too wet - Use dry wood Buildup 2) Turning down air control - Do not turn down until: too soon a) there is a good bed of coals b) the wood is charred 3) Draft too low - Improper chimney height and/or diameter - Chimney plugged or restricted, check fl ue...
  • Page 21: Firebrick Installation

    Firebrick Installation Alderlea T5 Insert This package contains 18 full-size fi rebricks, as well as 1 cut-size brick. With the heater in the upright position, install fi rebricks as follows: - Place fi rebricks on the bottom of the heater fi rst. Total of 7 full-size and 1cut brick.
  • Page 22 NOTES: ALT5.CPINSB 180314-24...
  • Page 23: Label

    MODEL / MODÈLE: ALT5INS SERIES / SÉRIE: D INSTALL AND USE ONLY IN ACCORDANCE WITH PACIFIC ENERGY’S INSTALLATION AND OPERATING INSTRUCTIONS. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT CODES, RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA. INSTALL AND USE ONLY IN MASONRY OR FACTORY BUILT FIREPLACE. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
  • Page 24 PACIFIC ENERGY FIREPLACE PRODUCTS LTD. www.pacifi cenergy.net Technical Support: 1-250-748-1184 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Printed in Canada...

This manual is also suitable for:

Alt5

Table of Contents