INSTALLER
INFORMATION
Note: The following Simpson Duravent kits are
recommended for use with this appliance.
High-Wind
(Bristol 46DVA-CL33)
(Bedford 46DVA-CL34)
Prairie Co-Linear Kit
(Bristol 46DVA-CL33P)
(Bedford 46DVA-CL34P)
Only certified venting systems or components may
be installed with this fireplace.
1) Measure chimney height, cut flex liner (min.10')
as required. Mark one pipe at both ends to identify
combustion air intake pipe from flue outlet pipe.
2) Attach marked flex liner pipe to the intake side of
vent terminal. Seal and secure with sealant and
screws provided. Attach the other pipe to the outlet
side of vent terminal. Seal and secure with sealant
and screws provided.
3) Insert both flex liners from top of the chimney, down
through the damper opening.
4) Before attaching vent terminal to top of chimney,
apply a bead of caulking to top of clay liner. Slip
vent terminal over liner and secure in place with
lateral retaining bolts.
5) For larger chimneys, an optional flashing is
available which may be cut and fitted to suit. The
flashing attaches to the underside of the terminal
with four nuts provided. Caulk the flashing in place
to seal any gaps.
Figure 21: Flue Adaptor Plate Conections
5055.633-B

Venting

Figure 22: High Wind
Vent Terminal
18
Bedford has a 4 inch dia.
exhaust vent and a 3 inch
intake vent.
Bristol has both 3 inch dia.
exhaust and intake vents.
Exhaust
Intake
Intake Damper Position
Air
Air
adjustment may vary
depending on particular
installation
Figure 23: Venting
NOTE:
**NOTE**
Max Vent Height
50' (15.25m)
25'-50'
3/4" Open
16'-25'
1" Open
10'-16'
Full
Open
Min. Vent Height
10' (3m)
BRSL.BODYB
140515-44
BDFD.BODYB