INSTALLATION AND OPERATING TESTED and LISTED GUIDE to ULC S628 / UL 1482 Meets the U.S. Environmental Protection Model Agency's July 1990 Particulate Emission Standards Pacifi c VISTA INSERT Series - C 010606-20 VISTA INSERT-C 5055.3231...
Energy Technical program (WETT) - in Canada, Hearth Edu- cation Foundation (HEARTH) - in U.S.A. (or equivalent) are strongly recommended. Fig. # 1 Mantel or Top Facing with mantel shield e n t j a c Hearth 010606-20 VISTA INSERT-C...
Page 4
Combustible fl oor beyond the hearth must be protected from hot embers by non-combustible material extending 16” to the fi ring side and 8” to other sides of the unit. Fig. # 3 16” Non-combustible hearth Non-combustible fl oor covering VISTA INSERT-C 010606-20...
When connected to a full liner, the Insert is able to and chimney, and will not reduce protection for combustible draft correctly and will prevent problems such as diffi cult materials to less than that required by the National Building start-ups and smoking out the door. Code. 010606-20 VISTA INSERT-C...
fi replace may be removed and stored on or within the fi replace for re-assembly if the Insert is removed. b: the chimney damper may be removed to install the liner. VISTA INSERT-C 010606-20...
fi t over the casing fl ange. (see Fig. #12) Pivot surround assembly up into place and secure with 2 screws in the upper corners of the casing. (see Fig. #13) Fig. # 12 Part C Part B Notch in Surround Base 010606-20 VISTA INSERT-C...
CSA C22.1 Canadian Electrical Code and in the USA Fig. # 14 with the National Electrical Code, ANSI/NFPA 70 (latest Knock-out Plug edition). Fig. # 15 Thermo By-pass Switch Rocker Switch Blower G (green) Speed Control L1 (white) L2 (black) VISTA INSERT-C 010606-20...
4) When burning at a slow rate for extended periods, oc- casionally maintain a strong fi re under supervision for a couple of hours to relieve fi rebox and chimney deposits as well as any of the deposits on the glass. 010606-20 VISTA INSERT-C...
An uncontrollable burn or a glowing red stove part or chimney indicates excessive draft. 3) Inadequate draft may cause backpuffi ng into the room and plugging of the chimney. Smoke leaking into the room through appliance and chimney connector joints indicates inadequate draft. VISTA INSERT-C 010606-20...
2000 degrees F. This causes much higher than normal temperatures in the chimney and on its exterior surfaces thus ignition of nearby or touching combustible material is more likely during a chimney fi re. Proper clearances are critical during such a fi re. 010606-20 VISTA INSERT-C...
Be careful as they are very sharp. Install new assembly and insulation by reversing order. Ensure that the glass complete with gasket. Replace frame and screws. insulation is not obstructing the fl ue outlet or the area above the baffl e. VISTA INSERT-C 010606-20...
1) Combustion air supply - Check outside air supply for obstructions Stove Won't Burn is blocked (see Combustion Air section) 2) Draft too low - Chimney plugged or restricted Inspect and clean - Chimney oversized or otherwise unsuitable Consult Dealer 010606-20 VISTA INSERT-C...
- Next, install the side fi rebricks, 2 each side. - Lastly, place 4 fi rebricks on the bottom of the heater. ITEM SIZE PART NUMBER 9” X 4 1/2” X 1 1/4” (230 mm x 115 mm x 32 mm) 5096.99 VISTA INSERT-C 010606-20...
Position the mantel shield over the holes and replace screws. Before tightening the screws, ensure the shield Mantel Shield is tight against the underside and the face of the surround. Surround Top 010606-20 VISTA INSERT-C...
8..Rocker Switch Wire ..........VINC.503221 15..Cord Strain Relief ..............5029 ..Blower Assembly Hardware (not shown) ....VINC.50335 All parts may be ordered from your nearest Pacifi c Energy dealer. Contact Pacifi c Energy for the location of the dealer near- est you. 010606-20 VISTA INSERT-C...
Attach hearth trim to the bottom of the surround with clips provided. The clips are installed up through the trim and into the surround. Surround Side Hearth Trim Clips VISTA INSERT-C 010606-20...
• INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE, CREOSOTE BUILDUP MAY OCCUR RAPIDLY. CAUTION MANUFACTURED BY: PACIFIC ENERGY FIREPLACE PRODUCTS LTD. PO. BOX 1060, DUNCAN, BC V9L 3Y2 HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE SKIN BURNS.
Page 20
PACIFIC ENERGY FIREPLACE PRODUCTS LTD. Phone: 1-877-715-2664 Web site: http://www.pacifi cenergy.net 2975 Allenby Rd., Duncan, B.C. V9L 6V8 Printed in Canada VISTA INSERT-C 010606-20...