Table of Contents

Advertisement

Note: The following Simpson Duravent kits are
recommended for use with this appliance.
(Broadway 46DVA-CL33)
(Brentwood 46DVA-CL34)
Prairie Co-Linear Kit
(Broadway 46DVA-CL33P)
(Brentwood 46DVA-CL34P)
Only certified venting systems or components may be
installed with this fireplace.
1.
Measure chimney height, cut ex liner (min.10') as
required. Mark one pipe at both ends to identify
combustion air intake pipe from ue outlet pipe.
2. Attach marked ex liner pipe to the intake side of vent
terminal. Seal and secure with sealant and screws
provided. Attach the other pipe to the outlet side of
vent terminal. Seal and secure with sealant and screws
provided.
3. Insert both ex liners from top of the chimney, down
through the damper opening.
4. Before attaching vent terminal to top of chimney, apply
a bead of caulking to top of clay liner. Slip vent terminal
over liner and secure in place with lateral retaining bolts.
5. For larger chimneys, an optional ashing is avail-
able which may be cut and tted to suit. The ashing
attaches to the underside of the terminal with four nuts
provided. Caulk the ashing in place to seal any gaps.
Figure 24: Flue adapter plate connections.
5055.66-B
High-Wind

Venting

Figure 25:
High wind
vent terminal.
Intake
Air
Figure 26: Co linear venting.
18
NOTE:
Brentwood has a 4 inch
dia. exhaust vent and a 3
inch intake vent.
Broadway has both 3
inch dia. exhaust and
intake vents.
**NOTE**
Exhaust
Intake Damper Position
Air
adjustment may vary
depending on particular
installation
Max Vent Height
50' (15.25m)
25'-50'
3/4" Open
16'-25'
1" Open
10'-16'
Full Open
Min. Vent Height
10' (3m)
230216-44
BDWY.BODYB
BRNT.BODYB