NetApp NearStore R100 Hardware And Service Manual page 145

Table of Contents

Advertisement

POST error message
*Overtemp alert
*PCCRD init fail
*PCCRD reg error
*PCCRD seek err
*PCCRD track err
*PCCRD head err
*PCCRD format err
*PCCRD read err
*PCCRD setup err
*PS #1 failed
*PS #2 failed
*SIO error
*Watchdog failed
Chapter 9: Troubleshooting LCD Messages
Explanation
The internal temperature sensor
has detected a dangerously high
temperature that can damage the
system components inside the
chassis.
These messages indicate that the
CompactFlash card drive
subassembly failed.
If the chassis has a second power
supply, one of the power supplies
failed and the chassis is running
on the second power supply.
The chassis SIO or ISA bridge
chip failed its timer interrupt test.
The system cannot operate
properly without this function.
The chassis watchdog reset
hardware, used to reset the chassis
from a system hang condition, is
not functioning properly.
Fatal?
Corrective action
Yes
1. Power down the chassis.
2. Reduce the ambient
temperature to 40° C or
lower.
3. Make sure that you have
proper air circulation
through the chassis.
If the temperature inside
the chassis is not
excessively hot, the sensor
itself might have failed.
4. Replace the motherboard.
No
Replace the CompactFlash
card, the CompactFlash card
reader subassembly, or the
motherboard.
No
Replace the identified power
supply.
Yes
Replace the motherboard.
No
Replace the motherboard.
135