POST error message
*Env-A stat err
*Env-B stat err
*Env-C stat err
*Env-D stat err
*Fan(s) stopped
*FLPY init fail
*FLPY reg error
*FLPY seek err
*FLPY track err
*FLPY head err
*FLPY format err
*FLPY read err
*FLPY setup err
*FP button stuck
*LCD won't open
*LCD cmd stall
*LCD cursor err
*LCD data error
*No power info
*Onboard battery low
134
Explanation
One of four environmental status
monitors on the chassis indicates
that it cannot properly monitor its
environmental health.
One or more chassis fans stopped
spinning or are spinning too
slowly. If two or more chassis fans
fail, the system does not boot.
These messages indicate that the
diskette drive subassembly failed.
The front panel Reset button is
stuck.
The system LCD device is not
operating correctly. All
subsequent POST messages are
displayed on the console.
The system is clearly running but
no information about the power
supply is being reported.
Something is wrong with the
power supply or the status
reporting circuitry.
The lithium battery on the
motherboard is low.
Fatal?
Corrective action
Yes
Replace the motherboard.
Maybe
Replace the chassis fan
subassembly containing the
failed fan.
No
Replace the diskette drive
subassembly or replace the
motherboard.
Yes
1. Make sure that the button
is not stuck.
2. Replace the LED/LCD
subassembly.
3. Replace the motherboard.
No
Replace the LED/LCD
subassembly or replace the
motherboard.
No
Replace the power supply or
the motherboard.
No
Replace the lithium battery on
the motherboard.
POST error messages