To change this setting:
1.
From the Diagnostics Menu, navigate to PRINTER SETUP.
Select Par 1 Strobe Adj.
2.
Touch
3.
Touch Submit to save the setting, or touch Back to return to the Diagnostics Menu without saving any
4.
changes.
Permanent Page Count
The value of this setting indicates the total number of pages that have been printed by the device.
Reset Color Calibration
This setting enables the device to adjust the alignment of its color planes using pre-programmed default values.
Using this setting to adjust color plane linearization may not provide a calibration as effective as using Automatic
Color Adjust Calibration. While this text executes, the panel posts Resetting.
Serial Number
This setting records the device's 13-character (last character is a null value) serial number that was assigned by
manufacturing.
U.S. / Non-U.S. Defaults
The value of this setting determines whether the device uses the U.S. or Non-U.S. factory default value.
To change this setting:
From the Diagnostics Menu, navigate to PRINTER SETUP.
1.
2.
Select Defaults.
Touch
3.
Touch Submit to save the setting, or touch Back to return to the Diagnostics Menu without saving any
4.
changes.
REPORTS
This menu contains informational reports that are helpful when servicing a device.
The Menu Settings Page report generates a list of the Diagnostic Menu settings and each setting's current
value.
SENSOR TESTS
PRINTER SENSOR TESTS
This test verifies that the sensors in the base machine are operating properly.
To run these tests:
From the Diagnostics Menu, navigate to SENSOR TESTS.
1.
2.
Select PRINTER SENSOR TESTS.
Select the test from the following options:
3.
Available tests:
• Sensor (transparency detect)
• Sensor (transfer belt HP)
or
to change the value.
or
to change the value.
• Sensor (MPF media level)
• Sensor (upper redrive)