5058-030
Warning: The following step must be performed, or the new machine settings will not match the
5
Retrieve the birth certificate from the compartment (1) in the media tray 1.
Using the the same Coefficient and Offset NVM values taken from step 2, overwrite the following
settings found on the birth certificate:
• ATC Setup Coefficient for Y
• ATC Setup Coefficient for M
• ATC Setup Coefficient for C
• ATC Setup Coefficient for K
• ATC Setup Offset for Y
• ATC Setup Offset for M
• ATC Setup Offset for C
• ATC Setup Offset for K
Return the birth certificate to the settings sheet compartment (1).
Exit diagnostics mode and perform a print test.
6

ATC value conversion chart

Barcode number
(last 2 digits)
00
01
02
03
04
05
06
07
08
09
10
11
Service Manual
4-386
settings listed on the birth certificate if it is required for NVM value replacement.
ATC Setup Coefficient Value
1638
1462
1321
1204
1107
1024
952
890
835
787
1638
1462
1
ATC Setup Offset Value
-266
-181
-133
-56
-9
31
66
96
123
146
-276
-190