Step
Action and questions
POR the machine.
3
Does the error continue?
175.05 Suction fan failure
Step
Action and questions
Check the suction fan.
1
Is the above component
properly connected?
Replace the suction fan. Go to
2
"Suction fan removal" on
page
4-168.
Does the error continue?
POR the machine.
3
Does the error continue?
175.06 Center exhaust fan failure
Step
Action and questions
Check the center exhaust fan.
1
Is the above component
properly connected?
Replace the center exhaust fan.
2
Does the error continue?
POR the machine.
3
Does the error continue?
175.07 Fuser driver PCBA cooling fan failure
Step
Action and questions
Check the fuser driver PCBA
1
cooling fan.
Is the above component
properly connected?
Yes
Replace the upper printer engine
PCBA.
Go to
"Upper printer engine
PCBA removal" on page
4-180.
Yes
Go to step 2.
Go to step 3.
Replace the upper printer engine
PCBA.
Go to
"Upper printer engine
PCBA removal" on page
4-180.
Yes
Go to step 2.
Go to step 3.
Replace the lower engine PCBA.
Go to
"Lower engine PCBA
removal" on page
4-98.
Yes
Go to step 2.
5058-030
No
Problem resolved
No
Replace the connections.
Problem resolved
Problem resolved
No
Replace the connections.
Problem resolved
Problem resolved
No
Replace the connections.
Diagnostic information
Previous
Next
Go Back
2-75