Fon; Gdi; Giv; Glh - AMX NXD-1200VG Operation/Reference Manual

Vg series modero 12" / 15"/ 17"
Hide thumbs Also See for NXD-1200VG:
Table of Contents

Advertisement

Programming
"^" Button Commands (Cont.)

^FON

^GDI

^GIV

^GLH

182
Set a font to a specific Font ID value for those buttons with a defined address range. Font ID numbers are
generated by the TPDesign4 programmers report.
Syntax:
"'^FON-<vt addr range>,<button states range>,<font value>'"
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
font value = range = 1 - XXX. Refer to theDefault Font Styles and ID Numbers table on page 168.
Example:
SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"
Sets the font size to font ID #4 for the On and Off states of buttons with the variable text range of 500-504
& 510-515.
Note: The Font ID is generated by TPD4 and is located in TPD4 through the Main menu. Panel >
Generate Programmer's Report >Text Only Format >Readme.txt.
Change the bargraph drag increment.
Syntax:
"'^GDI-<vt addr range>,<bargraph drag increment>'"
Variable:
variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.
Example:
SEND_COMMAND Panel,"'^GDI-7,128'"
Sets the bargraph with variable text 7 to a drag increment of 128.
Invert the joystick axis and move the origin to another corner. Parameters 1,2, and 3 will cause a bargraph
or slider to be inverted regardless of orientation. Their effect will be as described for joysticks.
Syntax:
"'^GIV-<vt addr range>,<joystick axis to invert>'"
Variable:
variable text address range = 1 - 4000.
joystick axis to invert = 0 - 3.
0
1
2
3
For a bargraph 1 = Invert , 0 = Non Invert
Example:
SEND_COMMAND Panel,"'^GIV-500,3'"
Inverts the joystick axis origin to the bottom right corner.
Change the bargraph upper limit.
Syntax:
"'^GLH-<vt addr range>,<bargraph hi>'"
Variable:
variable text address range = 1 - 4000.
bargraph limit range = 1 - 65535 (bargraph upper limit range).
Example:
SEND_COMMAND Panel,"'^GLH-500,1000'"
Changes the bargraph upper limit to 1000.
0 = Normal
1 = Invert horizontal axis
2 = Invert vertical axis
3 = Invert both axis locations
VG Series Modero Touch Panels

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxt-1500vgNxt-1700vgNxd-1500vgNxt-1200vgNxd-1700vg

Table of Contents