12.
Reconnect the terminal power connector on the 12 VDC-compliant power supply and apply power.

Wiring Guidelines for the 1200VG and 1500VG Panels

These Modero panels use a 12 VDC-compliant power supply to provide power to the panel via the 2-pin 3.5 mm mini-
Phoenix PWR connector. Use the previously referenced power requirements to determine the power draw.
The incoming PWR and GND wires from the power supply must be connected to the corresponding locations within the
PWR connector.
These units should only have one source of incoming power. Using more than one
source of power to the touch panel can result in damage to the internal components
and a possible burn out.
Apply power to the panels only after installation is complete.

Preparing captive wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.
Never pre-tin wires for compression-type connections.
1.
Strip 0.25 inch (6.35 mm) of insulation off all wires.
2.
Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector
types described in this section).
3.
Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively; doing so may strip the
threads and damage the connector.

Wiring a power connection

To use the 2-pin 3.5 mm mini-Phoenix connector with a 12 VDC-compliant power supply, the incoming PWR and GND
wires from the external source must be connected to their corresponding locations on the connector (FIG. 48).
PWR +
GND -
To the Touch Panel
FIG. 48
NetLinx power connector wiring diagram
1.
Insert the PWR and GND wires on the terminal end of the 2-pin 3.5 mm mini-Phoenix cable. Match the wiring
locations of the +/- on both the power supply and the terminal connector.
2.
Tighten the clamp to secure the two wires. Do not tighten the screws excessively; doing so may strip the threads and
damage the connector.
3.
Verify the connection of the 2-pin 3.5 mm mini-Phoenix to the power supply.
VG Series Modero Touch Panels
Installation Procedures: 12" and 15" Panels
Power Supply
57