Master Connection - Virtual Master Communication Over Ethernet - AMX NXD-1200VG Operation/Reference Manual

Vg series modero 12" / 15"/ 17"
Hide thumbs Also See for NXD-1200VG:
Table of Contents

Advertisement

Master Connection - Virtual Master communication over Ethernet

When configuring your panel to communicate with a Virtual Master (on your PC) via
Ethernet, the Master IP/URL field must be configured to match the IP Address of the
PC and make sure to use the Virtual System value assigned to the Virtual Master
within NetLinx Studio.
Before beginning:
1.
Verify the panel has been configured to communicate either through an Ethernet cable (connected from either the
panel to a valid Ethernet Hub) or wireless to the Wireless Access Point.
2.
Launch NetLinx Studio 2.x (default location is Start > Programs > AMX Control Disc > NetLinx Studio 2 >
NetLinx Studio 2).
3.
Select Settings > Master Communication Settings, from the Main menu to open the Master Communication
Settings dialog (FIG. 82).
IP Addresses of computer
(also obtained by using the
Start > Run > cmd command)
on the System Settings page
FIG. 82
Assigning Communication Settings and TCP/IP Settings for a Virtual Master
4.
Click the Communications Settings button to open the Communications Settings dialog.
5.
Click on the NetLinx Master radio button (from the Platform Selection section) to indicate that you are working as
a NetLinx Master.
6.
Click on the Virtual Master radio box (from the Transport Connection Option section) to indicate you are wanting
to configure the PC to communicate with a panel. Everything else such as the Authentication is greyed-out because
you are not going through the Master's UI.
7.
Click the Edit Settings button (on the Communications Settings dialog) to open the Virtual NetLinx Master
Settings dialog (FIG. 82).
8.
From within this dialog enter the System number (default is 1) and note the IP Address of the target PC being used
as the Virtual Master. This IP Address can also be obtained by following these procedures:

On your PC, click Start > Run to open the Run dialog.

Enter cmd into the Open field and click OK to open the command DOS prompt.

From the C:\> command line, enter ipconfig to display the IP Address of the PC. This information is entered
into the Master IP/URL field on the panel.
9.
Click OK three times to close the open dialogs, save your settings, and return to the main NetLinx Studio
application.
VG Series Modero Touch Panels
Enter this IP into the
Master IP/URL field
Configuring Communication
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nxt-1500vgNxt-1700vgNxd-1500vgNxt-1200vgNxd-1700vg

Table of Contents