CHAPTER 3 Work before Operating System Installation
3.5 Partition Configuration (Extended Partitioning)
Setting of Zoning
1.
Click [Partition]-[Extended Socket Configuration].
[Extended Socket Configuration] window is displayed. For details on [Extended Socket Configuration] window, see
of "1.3.6 [Extended Socket Configuration] menu" of PRIMEQUEST 2000 series Tool Reference (CA92344-0539).
FIGURE 3.39
2.
Select [Zone#] for each Extended Partition.
Zone which configured by FIGURE 3.39
below.
0
1
7
3.
Click [Apply] button.
Example of [Extended Socket Configuration] Window
Example of [Extended Socket Configuration] Window
TABLE 3.8 Example for Extended Socket (Zone) configuration
Zone#
Extended Partition included in Zone
Partition#7
Partition#8
Partition#4
Partition#9
Partition#11
Partition#6
Partition#10
57
is displayed
CA92344-0536-04