Login To Mmb; Table 3.5 Settings Required For Connecting External Lan - Fujitsu PRIMEQUEST 2000 Series Installation Manual

Hide thumbs Also See for PRIMEQUEST 2000 Series:
Table of Contents

Advertisement

CHAPTER 3 Work before Operating System Installation
3.3 Connection and Setting of MMB
Conditions
When using the switching hub which supports the
circulatory prevention function (Spanning Tree
Protocol or the domain Separation, etc.) in the
external switch
When the data given below corresponds to any of
the category-
-Destination server becomes external server which
is passed through the firewall.
-Use a mail server which restricts the IP address.
For REMCS connection
Remark
-
Packets are transmitted from MMB in "NTP", "Alarm E-Mail", and "REMCS". When both the physical IP address and
the virtual IP address of MMB are set, the transmission source IP address of packet is considered as the physical IP
address of the MMB.
-
Physical IP address of MMB is also used in PRIMECLUSTER linkage.

3.3.4 Login to MMB

The method of login to the MMB is described below.
Login/ Logout in MMB Web-UI
The procedure of Login/Logout for MMB Web-UI is described below.
Specify any of the following to login to Web-UI.
-
Virtual IP Address
-
Fully Qualified Domain Name (FQDN) corresponding Virtual IP Address
-
Hostname corresponding Virtual IP Address
Note
-
MMB Web-UI supports the following browsers. Note that, if the browser other than this is used, Web UI window may
not display correctly.
-
Internet Explorer 9 onwards
-
Firefox 20 onwards
-
Do not multiple login by using Web-UI from one MMB console PC to PRIMEQUEST 2000 series (also includes
multiple login with the same user name). If multiple login is done, the following phenomenon may occur by the types
and version of a browser to be operated. Moreover, do not multiple login by using multiple tabs.
-
The operation authority of the user logged in previously with Web-UI might change to the operation authority of the
user who logs in later.
-
When one Web-UI is logged out, all Web-UIs might be logged out.
Remark
To specify the FQDN, the DNS server should be set in the MMB console PC
For details on DNS server setting, see

TABLE 3.5 Settings required for connecting external LAN

Prevent circulatory prevention function to [disable] Spanning Tree Protocol
of connection port of switching hub and the main unit or to set Domain
Separation 'ON'.
It is necessary to set the firewall and mail server in such a way that
physical IP address packets of MMB #0 and MMB#1 can pass through.
Connection format is as given below.
-
When connecting to internet:
Connect REMCS port to the external switching hub. Or connect to the
center by restricting the firewall from the external switch of the
management port.
-
When connecting to P-P
Connect each REMCS port of MMB of MMB#0 and MMB#1 to the Dial-
up route directly.
For details on REMCS linkage, see PRIMEQUEST 2000 series REMCS
Service Installation Manual (CA92344-0542).
"3.3.8 Configuration of DNS
Required settings
server",
16
CA92344-0536-04

Advertisement

Table of Contents
loading

Table of Contents