Clock Pre-Scaler; Pulse Generator Selector; Pulse Generator Length - JAI GO-5000M-USB User Manual

5m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Table – 7
Pulse Generator default settings
Display Name

Clock Pre-scaler

Pulse Generator
Selector
-
Pulse Generator 0
Note: When Pulse Generator Repeat Count is set to "0", the camera is operating in Free Running mode.
However, based on the above default setting, Length=1, Start Point=0 and End Point=1, Pulse Generator stops at
High output. Therefore, if Start Point=0 and End Point=1 are configured, Length should be "2" as the minimum
active width.
6.5.1
Clock Pre-scaler
Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit
length) and the pixel clock is used for this. A built-in pulse generator works by the same
clock. In the GO-5000-USB, the pixel clock is 48 MHz.
6.5.2

Pulse Generator Selector

GO-5000-USB has one pulse generator.
Table – 8
Pulse Generator setting
Trigger Selector
Description
item
If Pulse Generator 0 is selected, Length Start Point, End Point, Repeat Count, Clear Source, Clear
Pulse Generator 0
Inverter, Clear Activation, and Clear Sync Mode of pulse generator 0 are displayed under the
selector.
Pulse generator
Clear source IN
(Clear activation
= Rising edge
Clear SYNC mode
= Async)
Pulse generator
Output
6.5.3

Pulse Generator Length

Set the counter up value (number of clocks, refer to Table 14) for the selected pulse generator.
If Repeat Count value is "0", and if Pulse Generator Clear signal is not input, the pulse
generator generates the pulse repeatedly until reaching this counter up value.
GO-5000M-USB / GO-5000C-USB
Value
1
Pulse Generator
Length
Start
End
Point
Point
1
0
1
Pulse generator repeat count = N
(Pulse generator length x N)
Pulse generator
length
0
0
Pulse generator End point
Pulse generator Start point
Fig.11
Pulse Generator pulse construction
Repeat
Clear
Clear
Count
Source
Inverter
0
Off
True
Pulse generator
length
- 19 -
Clear
Clear
Activation
Sync
Mode
Off
Async Mode
Pulse generator
length
0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Go-5000c-usb

Table of Contents