Trigger Overlap; Normal Continuous Operation (Timed Exposure Mode/Trigger Mode Off); Timed Mode - JAI GO-5000M-USB User Manual

5m digital progressive scan monochrome and color camera
Table of Contents

Advertisement

Rising Edge:
Falling Edge:
Level High:
Level Low:
Table – 21
Camera Settings
Trigger
Selector
Frame
Start
Note: When Trigger Width mode is used, the level High or level Low must be used.
8.3.5

Trigger Overlap

In the GO-5000-USB, the trigger overlap function is fixed to Read Out.
Read Out:
8.4.

Normal continuous operation (Timed Exposure Mode/Trigger Mode OFF)

This is used for applications which do not require triggering.
Primary settings to use this mode
Trigger Mode: Off
Minimum interval of the frame
Read out mode
Full
ROI 1/2 (Height=1024)
ROI 1/4 (Height=512)
1/2V Binning (Note 1)
(Note1) GO-5000M-USB only
8.5.

Timed mode

This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. Additional settings determine if the trigger pulse can be accepted during the
exposure period.
Primary settings to use this mode
Exposure Mode: Timed
Trigger Mode: ON
Trigger Option: OFF
Optical Filter Selector: 10 µs
GO-5000M-USB / GO-5000C-USB
At the rising edge of the pulse, the trigger is activated.
At the falling edge of the pulse, the trigger is activated.
During the High level of the trigger, the accumulation is activated.
During the Low level of the trigger, the accumulation is activated.
Trigger Activation
Trigger
Trigger
Exposure
Option
Mode
Mode
On
Timed
Off
On
Timed
RCT
On
Trigger
Off
Width
The trigger pulse can be accepted during the sensor readout.
Trigger Activation Setting
Rising
Falling
Edge
Edge
×
×
Minimum trigger interval
16.155 ms
8.092 ms
4.07 ms
8.092 ms
- 40 -
Level
Level
High
Low
×
×
×
×