6.5.10

Pulse Generator Inverter

Clear Source Signal can have polarity inverted.
6.5.11

Pulse Generator Setting Parameters

Table – 10
Pulse Generator setting parameters
Display Name
Clock Pre-scaler
Pulse Generator Clock (MHz)
Pulse Generator Selector
- Pulse Generator Length
- Pulse Generator Length (ms)
- Pulse Generator Frequency (Hz)
- Pulse Generator Start Point
- Pulse Generator Start Point (ms)
- Pulse Generator End Point
- Pulse Generator End Point (ms)
- Pulse Generator pulse-width (ms)
- Pulse Generator Repeat Count
- Pulse Generator Clear Activation
Clear Mode for the Pulse Generators
- Pulse Generator Clear Sync Mode
- Pulse Generator Clear Source
- Pulse Generator Inverter(Polarity)
Pulse Generator Clear Inverter
Note:
1. If Pulse Generator Repeat Count is set to "0", the pulse generator works in free-running mode.
GO-5000M-USB / GO-5000C-USB
Value
1 to 4096
[Pixel Generator Tick Frequency: 48MHz]÷[Clock Pre-scaler]
- Pulse Generator 0
- Pulse Generator 1
1 to 1048575
([Clock Source]÷[Clock Pre-scaler])
[Pulse Generator Length (ms)]
0 to 1048574
([Clock Source]÷[Clock Pre-scaler])
1 to 1048575
([Clock Source]÷[Clock Pre-scaler])
[ Pulse Generator End Point (ms)]-[ Pulse Generator Start Point (ms)]
0 to 255
- Off
- High Level
- Low level
- Rising Edge
- Falling Edge
- Async mode
- Sync mode
- Low
- High
- Acquisition Trigger Wait
- Acquisition Active
- Frame Trigger Wait
- Frame Active
- Exposure Active
- Fval
- Lval
- User output 0
- User output 1
- OPT In
- NAND0 Out
- NAND1 Out
- False
- True
- 22 -
-1
x [Pulse Generator Length]
-1
-1
x [Pulse Generator Start Point]
-1
x [Pulse Generator End Point]