6.3.2.

Pre-select Trigger Mode

An external trigger pulse initiates the capture, and the exposure time (accumulation time) is
defined by the SH or PE commands.
The resulting video signal will start to be read out after the selected shutter time.
For timing details, refer to fig. 8 through fig. 13 and fig. 14 & 15.
To use this mode:
Set function:
Input:
Important notes on using this mode
1. The minimum trigger interval >1 LVAL.
2. Depending on the timing of the leading edge of the trigger pulse in relationship to
FVAL, accumulation will be synchronous or a-synchronous in relationship to LVAL. See
chapter 6.1.5 for details.
LVAL_sync timing
LVAL SYNC
TRIG
LVAL
CCD Expsoure
EEN
FVAL
In case the trigger pulse is input during FVAL being HIGH,
LVAL sync accumulation is initiated.
CM-030PMCL-RH
Trigger mode to "Edge pre-select"
Scanning
V Binning
Shutter mode to pre-set or programmable
SM=0 or 1
Shutter speed
SH=0 to 9
Programmable exp.
Other functions and settings
Ext. trigger. Camera Link or 12-pin Hirose
2L(min)
1L~2L
Fig. 14. Pre-select trigger mode. LVAL synchronized.
Exposure
FULL:6L (97.44us)
Vbinni ng:4L(80.28us)
18
TR=1
SC=0 to 4
VB=0 or 1
PE=2 to 511
TI=0, TI=1