8.10
Delayed Readout function
The images captured by Frame Start trigger can be stored inside the camera and readout by
Acquisition Transfer Start trigger. Up to 7 frames can be stored.
Table-27 Delayed readout command
Command
Trigger Selector
Trigger Mode
Trigger Source
Trigger Activation
GO-5000M-USB / GO-5000C-USB
Index 4
Offset X
Index 3
Offset X
Index 2
Offset X
Index 1
Index 1
Offset X
Width
ROI 1
Fig.29
Multi ROI setting example
Setting
Acquisition Transfer Start
On
Select the source to be
used
Select the polarity of the
source to be used.
Index 3
Width
Index 2
Width
ROI 2
ROI 3
H-Binning Off
Width Max = 2560
Select the Trigger Selector at Acquisition
Transfer Start to operate this function.
Refer to Chapter 8.3
- 49 -
Index 4
Width
ROI 4
Description