Christie CP4230 User Manual page 31

Hide thumbs Also See for CP4230:
Table of Contents

Advertisement

washers and lock washers properly in place and tighten to 175 inch-lbs, 14 ft-lbs or 20Nm
at both ends to prevent them from coming loose.
g. Connect the negative (-) black lamp lead to the negative (-) igniter terminal, left terminal. Connect the
positive (+) red lamp lead to the positive (+) igniter terminal, right terminal. CAUTION! When tight-
ening the positive and negative leads, do not tighten to the point that the brackets start to bend. Use an
adjustable wrench to support the brackets when tightening.
h. Tighten the strain reliefs.
i. Replace the igniter safety cage.
3. Move the AC Input Line Voltage switch in the upper-left corner of the LPS to the left if you are using a 200
VAC supply, or right if you are using a 400 VAC supply.
4. Connect the AC directly to the LPS with an AC Input Terminal Block that is correct for your region.
CAUTION!
ensure adequate environmental sealing and to prevent the cable from accidentally being torn out.
• For North America, Japan and most of Central/South America (
Wire Phase 1, 2, 3 and Ground
• For Europe, (380-415 VAC):
Wire Phase 1, 2, 3, Neutral and Ground
5. Connect one end of the LPS power cord into the socket on the LPS labeled CP2230/4230 cinema
projector ONLY. Connect the other end of the power cord into the socket on the front of the cinema
projector.
WARNING!
must terminate the power connector terminal block correctly to ensure 200VAC-240VAC output. These
connectors are controlled with the power connector breaker. For more information, see the Interconnect
Drawing provided with your cinema projector.
6. Turn the LPS Breaker on.
7. If you are using the extraction unit and cinema projector power connectors, turn them on.
CP4230 User Manual
020-100621-03 Rev. 1 (05-2014)
Use an appropriately sized strain relief connector with the knockout plate provided to
If you use the power connectors to power the cinema projector or the extraction unit, you
to extractor
(optional)
Communication
cables
CP4230 Projector &
Extraction Unit Power
Connectors
Connect to AC at site
NOTE: Shroud removed for clarity
Section 2: Installation and Setup
190-208 VAC):
Lamp leads
to projector
2-17

Advertisement

Table of Contents
loading