Section 2: Installation and Setup
As shipped
200V
400V
Power Connectors (optional)
Must terminate the power connector terminal
block correctly to ensure 200VAC-240VAC
output. Line cord provided for connection
to projector only.
Power Connector Breaker
(On = up position)
1. Connect the LPS Communication Cables:
a. Remove the 2 cover plate thumbscrews from the cinema projector's baseplate in the LVPS compart-
ment.
b. Connect one end of the RS232 cable to the port on the LPS labeled RS232. Route the cable up through
the opening in the cinema projector's baseplate into the LVPS compartment. Connect the other end of
the RS232 cable to the port labeled RS232 in the LVPS compartment.
c. Connect one end of the Interlock cable to the port on the LPS labeled Interlocks. Route the cable up
through the opening in the cinema projector's baseplate that you ran the RS232 cable. Connect the
other end of the Interlock cable to the port labeled Interlock in the LVPS compartment.
2. Connect the Lamp Leads:
a. Open the LVPS access door and remove the four hex screws from the safety cage front panel. Lift the
front panel over the igniter.
b. Loosen the 6 screws to remove the LPS side panel.
c. Route the cables through the strain reliefs in the LPS cover.
d. Connect the positive (+) and negative (-) lamp leads to the terminals on the LPS using a torque setting
of 14ft/lbs (20N/m).
e. Tighten the strain reliefs.
f. Route the positive and negative leads from the LPS through the two strain reliefs in the cinema projec-
tor baseplate.
Igniter make sure the black (-) power cable (cathode lead) is securely connected with the
2-16
3
LPS Breaker
Phase Status LEDs
4.
When connecting the high current lamp leads between the LPS and the
Configure the LPS for incoming AC
NOTE: Internal
Input Line Voltage
switch setting
must match AC available at the site.
Power Connector
Terminal Block
AC Input
Terminal Block
Earth Ground
Connect to 3-phase AC supply:
• 208 VAC in N. America
• 200 VAC in Japan
• 380-415 VAC in Europe
Line cord not supplied. Must supply
appropriate strain relief.
Interlocks
Connect communication
1
cables to projector
(inside LVPS compartment)
RS232
+ DC
Connect lamp leads
2
– DC
to projector (to igniter)
CP4230 User Manual
020-100621-03 Rev. 1 (05-2014)