Lamp Hours (LPH) (Continued)
NONE
Return lamp usage for current lamp in hours.
TLSK
Return total lamp strikes on the installed lamp
EXAMPLES:
(LPH?) Get usage in hours
(LPH+FLSK?) Get lamp strikes
Lamp Intensity (LPI)
Set lamp intensity setpoint. The value is used when lamp mode is set to LiteLOC™. The cinema projector will
adjust the Lamp Power to maintain this intensity. NOTE: This command can only be used to update the current
lamp file. Changing the lamp intensity for the current channel will change the lamp intensity for any channel using
the same lamp file.
SUBCODE
DESCRIPTION OF USE
Cxxx
Replace Cxxx with the channel number. Valid range is 101-164.
NONE
Set lamp intensity for the current channel.
EXAMPLES:
(LPI 4500) Set lamp intensity to 4500 for current channel
(LPI+C103 4000) Set the lamp intensity to 4000 for channel 3
(LPI?) Get lamp intensity for the active channel
Lamp Life (LPL)
Set/get expected lamp life in hours. The default hours will be used if lamp life is 'not set'. Lamp expiry message
will be sent out when lamp usage is over the lamp life.
SUBCODE
DESCRIPTION OF USE
LIFE
0 - No warning will be generated.
1 - Lamp Life Expiry Warning will be generated when lamp hours extends past lamp life. Warning will be
reported in SST. Warning will be cleared by extending lamp life or changing the lamp.
NONE
Set or get expected lamp life.
ROTA
Set to 1 acknowledge the Lamp Rotation Warning. Will auto clear at lamp life or on lamp change.
ROTW
0 - No warning will be generated.
1 - Lamp Rotation Warning will be generated when lamp hours extends past 1/2 lamp life. Warning will be
reported in SST. Warning will be cleared by LPL+ROTA or changing the lamp.
EXAMPLES:
(LPL 1500) Set lamp life limit to 500 hours.
(LPL 0) Set lamp life limit to default hours based on the lamp type.
(LPL ?) Get lamp life limit.
(LPL+LIFE 1) Enable lamp expired message.
(LPL+LIFE 0) Disable lamp expired message.
(LPL+ROTW 1) Enable lamp rotation message.
(LPL+ROTA 1) Acknowledge that lamp was rotated.
CP4230 User Manual
020-100621-03 Rev. 1 (05-2014)
Appendix B: Serial API