22.Specifications

22.Specifications
Name
Model
Power Supply
Electric Shock Protection Type
Operating Temperature and Humidity
Storage Temperature and Humidity
Weight
External Dimensions
Package Contents
Options
Basic Specifications for Blood Pressure Measurement
Display Method
Degree of Protection
Measurement Method
Measurement Range
Accuracy
Inflation
Deflation
Exhaust
Pressure Detection
Basic Specifications for Pulse Wave Measurement
Measurement Method
Degree of Protection
Measurement Range
Inflation
Deflation
Exhaust
Included Memory Card (128MB)
Storable Data Amount
92
OMRON Non - Invasive Blood Pressure Monitor with Augmentation Index
HEM-9000AI
AC100 V - 240 V 50/60 Hz 150 VA
Class I
+10 - +40°C / 15 – 85% RH
-20 - +60°C / 10 – 95% RH
Main unit approx. 5.3 kg
(Power plug and connection cable included; cuff, printer paper and
memory card not included.)
AI Measurement Unit 1.3 kg
(Including the AI pulse wave sensor unit)
Main unit : W 240 mm x H 260 mm x D 235 mm
AI Pulse wave sensor unit : W 140 mm x H 55 mm x D 60 mm
AI Pulse wave Measurement Unit :
W 170 mm x H 145 mm x D 315 – 410 mm
Main unit, Al Pulse Wave Measurement Unit, Adult arm cuff (in 3 sizes -
S, M and L with built-in air bag), air tube (1.3 m), connection cable, power
cord, printer paper, memory card (128MB), instruction manual, Quick
Start Instruction Manual
large size adult arm cuff, medium size adult arm cuff, small size adult arm
cuff, air tube (1.0 m), wheeled cart, printer paper, keyboard, memory
card, power code
8.4 inch (800 x 600 pixels) colour TFT LCD
Type BF
Oscillometric Method
Pressure 0 – 299 mmHg
Pulse 30 – 199 pulse/minute
Pressure: Within ±3 mmHg
Pulse Rate: Within ±5% of reading
Automatic Inflation Method by Pump
Automatic Deflation Method by Electromagnetic Control Valve
Automatic Rapid Exhaust Method by Electromagnetic Control Valve
Electrostatic Capacity Method Semiconductor Pressure Sensor
Applanation Tonometry
Type BF
Pulse 30 – 199 pulse/minute
Automatic Inflation Method by Pump
Automatic Deflation Method by Electromagnetic Valve
Automatic Rapid Exhaust Method By Electromagnetic Valve
Without PULSE WAVE DATA:
approximately 6,400 measurements
With PULSE WAVE DATA:
approximately 320 measurements
(for 30-second measurements)