Omron HEM-9000AI Instruction Manual

Non-invasive blood pressure monitor with augmentation index (ai)
Hide thumbs Also See for HEM-9000AI:
Table of Contents

Advertisement

Blood Pressure Monitor
with Augmentation Index (AI)
• Instruction Manual
• Mode d'emploi
• Gebrauchsanweisung
• Manuale de instructone
• Manual de instrucciones
• Gebruiksaanwijzing
XXXXXXXXXXXXXXXXXXXXXXXX
Thank you for purchasing the OMRON HEM-9000AI unit.
Read all of the instructions in the instruction manual before you operate the unit
and keep it near the unit all the times for future reference.
HEM-9000AI
Non-Invasive
EN
FR
DE
IT
ES
NL
CZ
IM-HEM9000-AI-E-01-07/06

Advertisement

Table of Contents
loading

Summary of Contents for Omron HEM-9000AI

  • Page 1 • Manual de instrucciones • Gebruiksaanwijzing • XXXXXXXXXXXXXXXXXXXXXXXX Thank you for purchasing the OMRON HEM-9000AI unit. Read all of the instructions in the instruction manual before you operate the unit and keep it near the unit all the times for future reference. IM-HEM9000-AI-E-01-07/06...
  • Page 2: Table Of Contents

    5.1. Main Unit ................12 5.2. Accessories (Included and Sold Separately) ...... 12 6. Accessories ................13 7. Introduction to the HEM-9000AI ..........14 8. General Preparation ..............15 8.1. Component Names/Descriptions ........15 8.2. Connecting the Main Unit and AI Pulse Wave Measurement Unit Inserting the Memory Card ....
  • Page 3 16 Memory Retrieval ............... 46 16.1. Show All Data List ............... 46 16.2. ID Search ................48 16.3. Delete Data ................. 49 16.4. Data Detail ................50 16.5. Print Continuous Pulse Waves ........... 51 16.6. Trend Graph ................ 53 16.7. Adding and Modifying Blood Pressure Measurement Values ............
  • Page 4: Indications

    1. Indications Indications for use The HEM-9000AI is intended to measure systolic and diastolic blood pressure and pulse rate in adults with an arm circumference of 17-42 cm, and to calculate radial augmentation index (AI). The HEM-9000AI is intended for use in physicians’ offices, hospitals, clinics and other medical facilities where non-invasive blood pressure and radial AI measurements/calculations are performed on patients and invasive measurement is contraindicated.
  • Page 5: Exemptions

    However, if an inadequate description or error is found, please let us know. 3.It is prohibited to copy a part of or the entire lnstruction Manual without obtaining OMRON’s permission. Unless this lnstruction Manual is used by an individual (company), it cannot be...
  • Page 6: Notes On Safety

    3.Notes on Safety 3. Notes on Safety GIVE PARTICULAR ATTENTION TO ALL SAFETY PRECAUTIONS Warning signs and graphic symbols are intended for the safe and correct use of the product, and to prevent harm or damage to you and others. Symbols and definitions are as follows: Indicates a possibility that people will suffer death or serious injury resulting from Warning...
  • Page 7 • If the following cases or situations occur, stop using this device immediately, turn it off, unplug the power cord from the outlet, and contact OMRON. • If there is smoke or an unusual order. • If this device is dropped or subject to a strong impact.
  • Page 8 • Do not disassemble or modify this device. • Electric shock, fire, failure or malfunction might result. • Do not use with any cuffs except those provided by OMRON specifically for this device and model. • It might cause incorrect measurement results.
  • Page 9 3.Notes on Safety Caution: Clinical • When results seems unreliable, use other measurement procedures prior to invasive techniques. • Make sure that the patient does not touch this device while the test is being conducted. • Only measure when the patient is quiet, not talking or moving. •...
  • Page 10 3.Notes on Safety • Do not use any printer paper other than the printer paper provided by OMRON specifically for this device and model. • Damage to the printer might result. • Printed text, waveforms and measurement results may smear or fade.
  • Page 11: Cleaning And Maintenance

    4.Cleaning and Maintenance 4. Cleaning and Maintenance Maintenance prior to use 1. Check this device regularly. 2. When not in use for a long time, ensure that this device functions correctly and safely before using it. • Check all cord, cable and tube connections. •...
  • Page 12: Package Contents

    5.Package Contents 5. Package Contents 5.1. Main Unit AI Pulse Wave Measurement Unit Main Unit (display unit) (Including the AI pulse wave sensor unit) 5.2. ACCESSORIES (Included and Sold Separately) Connection Cable Adult arm cuff Air Tube (1.3 m) Model: HEM-9000-CABLEZ (in 3 sizes - S, M and L with built-in air bag) Model: HEM-9T1.3 Art no.: 9956251-4...
  • Page 13: Accessories

    (with basket to place cuff) Model: HEM-9000-IC128Z Model: HEM-9000-STANDZ Art no.: 9956250-6 Art no.: 7980234-9 • Printer Paper (5 Roll Set) • Power Cord (for U.K.) Model: HEM-9000-PAPERZ Model: HEM-9000-ACCAU Art no.: 6970159-5 Art no.: 9983975-3 To purchase accessories or replacement parts call OMRON.
  • Page 14: Introduction To The Hem-9000Ai

    7. Introduction to the HEM-9000AI Functional Description The OMRON Non-Invasive Blood Pressure Monitor with AI, HEM-9000AI, has been developed for blood pressure measurement and AI calculations. Blood pressure measurement is obtained via digital oscillometric method using a blood pressure cuff. An...
  • Page 15: General Preparation

    8.General Preparation 8. General Preparation 8.1. Component Names/Descriptions A. Printer cover L. DISPLAY light B. Print paper storage (built-in) M.LCD display The material used in the front of the panel is C. Print paper release button PMMA. D. Air connector N.
  • Page 16 8.General Preparation A. Slide stoppers H. Elbow placement board B. Palpation window I. AI Pulse Wave sensor unit storage clip C. Base line J. Rubber wrist rest D. Indicator lights K. Main unit connector E. AI Pulse Wave sensor unit L.
  • Page 17: Connecting The Main Unit And Ai Pulse Wave Measurement Unit Inserting The Memory Card

    8.General Preparation 8.2. Connecting the Main Unit and AI Pulse Wave Measurement Unit Inserting the Memory Card Make sure that the power switch is in the OFF position. [Fig. 1] Insert the air plug of the blood pressure cuff in the air connector on the left side of the main unit.
  • Page 18 8.General Preparation Turning on the power, and checking the time/date Insert the memory card into the slot on the right side of the main unit. All measurement data will be saved to the memory card. The measurement results will not be saved if the memory card is not properly inserted in or if there is insufficient memory available on the card.
  • Page 19: Setting The Date And Time

    8.General Preparation 8.3. Setting the Date and Time Press the F5 key on a screen where F5 [SETUP] appears at the bottom. [Fig. 1] [Fig. 1] The setup screen will be displayed. Move the [ ] cursor in the upper-left part of the screen up or down using the [ ] buttons to select “DATE/TIME”...
  • Page 20 8.General Preparation To change the [DATE] under [DATE / TIME]: Move the [ ] cursor to [DATE] and press the SET button or the [ ] button. [Fig. 4] Move the [ ] cursor using the [ ] button to select the item (day/month/year) under [SETTING VALUE] to change.
  • Page 21 8.General Preparation Follow these steps to change the [TIME] under [DATE / TIME]: Change the time. Move the [ ] cursor to [TIME] and press the SET button or the [ ] button. [Fig. 6] Move the [ ] cursor using the [ ] button or the [ button to select the item (hour/minute/second) under [SETTING VALUE] to change.
  • Page 22: Setting The Blood Pressure/Ai Measurement Method And Registering Id Information

    8.General Preparation 8.4. Setting the Blood Pressure/AI Measurement Method and Registering ID Information Setting the Blood Pressure/AI Measurement Methods There are three methods for blood pressure measurement: Single, Average - 2 times, and Average - 3 times. The default setting is [SINGLE]. To change this setting, follow the instructions in Section 18.3.
  • Page 23: Loading Printer Paper

    Load the specially designed printer paper into the holder in the direction shown in the diagram. [Fig. 10] * Make sure you use OMRON printer paper, refer to Section 5.2. Load the printer paper as shown in the diagram. * Pull out the paper so that it protrudes from the printer cover when closing.
  • Page 24: Measurement Preparation

    9.Measurement Preparation 9. Measurement Preparation 9.1. How to Apply the Blood Pressure Cuff Select a cuff according to the circumference of the [Fig. 1] patient’s arm. [Fig. 1] Arm circumference Name of the arm cuff Large size adult arm cuff 17 - 22cm Small size adult arm cuff 22 - 32cm...
  • Page 25 * If after wrapping, INDEX, printed on the cuff, is misaligned with RANGE, select a different, more appropriate size cuff according to the circumference of the arm, and wrap again. * If not wrapped with appropriate cuff, the arm might become numb, or the HEM-9000AI might not be able to measure blood pressure correctly.
  • Page 26: How To Apply The Ai Pulse Wave Sensor Unit

    9.Measurement Preparation 9.2. How to Apply the AI Pulse Wave Sensor Unit AI measurement is intended only for adults with a wrist circumference of 10-19 cm around the radius protrusion. Proper posture Adjust the height of the chair to align the height of the wrist with the height of the heart.
  • Page 27 9.Measurement Preparation The Best Points for Taking an AI Measurement [Fig. 18] With the palm up, take the reading from the artery next to the protrusion of the radius on the thumb side. The best point is right next to the radius protrusion where the pulse is the strongest. If it is not possible to locate the radius protrusion, the best point is where the pulse feels the strongest in the area where the bone is close to the skin and is hard to the touch.
  • Page 28 9.Measurement Preparation Locate the radial artery by palpation. Once you have located the radial artery, use a commercially-available, non-permanent felt tip marker to mark the spot on the artery which will be Storage clip best for your AI pulse wave measurement. A proper measurement can only be done over the bone at the radial artery.
  • Page 29: Post - Measurement

    10.Post - Measurement 10.Post - Measurement 10.1. How to Remove the AI Pulse Wave Sensor Unit Check that measurements are complete. [Fig. 27] Push down the slide stoppers on both sides and return the sensor to its original position. Put the AI pulse wave sensor back in the storage clip.
  • Page 30: Selecting The Measurement Method

    11.Selecting the Measurement Method 11.Selecting the Measurement Method 11.1. Selecting the Measurement Method This device has the following three measurement options: AI + blood pressure measurement (1. below), blood pressure measurement (2. below), and AI measurement (3. below). Change the measurement option by pressing the F1 key [MODE] until the desired option is selected [Figs.
  • Page 31: Ai + Blood Pressure Measurement

    12.AI + Blood Pressure Measurement 12.AI + Blood Pressure Measurement 12.1. Measuring AI + Blood Pressure Together This section explains how to simultaneously measure AI and blood pressure using both arms. To measure AI and blood pressure alternately, follow the instructions in Section 18.3. to change the AI measurement sequence.
  • Page 32 12.AI + Blood Pressure Measurement How to incorporate the Tonogram display for a more accurate measurement: A tonogram shows the output of an AI pulse wave sensor. The positional relationship of the AI pulse wave sensor and an artery can be estimated from a tonogram. [Fig. 4] The values around the peak of the tonogram (around the centre of an artery) are calculated.
  • Page 33 12.AI + Blood Pressure Measurement As the AI pulse wave sensor pressure becomes stable, the pulse wave will be displayed in the upper left corner of the screen, and the actual measurement will begin. [Fig. 5] Instruct the patient not to move during measurement.
  • Page 34 12.AI + Blood Pressure Measurement A beep will sound* when the data has been saved. The dark blue message [COMPLETE] will be displayed at the lower left corner of the screen. [Fig. 7] The representative pulse wave (AVG) displayed on the screen is selected among all detected pulse waves.
  • Page 35 12.AI + Blood Pressure Measurement Press the [ ] buttons to display results from each pulse wave measurement. Example: If 35 waveforms are measured: 34/35 35/35 1/35 2/35 The pulse wave number is displayed below the waveform (in the left centre part of the screen). [Fig.
  • Page 36: Blood Pressure Measurement

    13.Blood Pressure Measurement 13.Blood Pressure Measurement 13.1. Blood Pressure Measurement This mode is for using the device solely as a blood pressure monitor. There are three blood pressure measurement options: [SINGLE], [AVERAGE - 2 TIMES], [AVERAGE - 3 TIMES]. Refer to Section 18.3.
  • Page 37 13.Blood Pressure Measurement The pulse wave level is displayed with a bar during measurement. [Fig. 5] [Fig. 5] Once measurement is complete the buzzer will Systolic blood sound* and the results will pressure value appear. [Fig. 6] Diastolic blood Deflation is automatic. Upon pressure value completion, a “COMPLETE”...
  • Page 38: Auscultation

    13.Blood Pressure Measurement 13.2. Auscultation When selecting blood pressure measurement, it is possible to take the reading using auscultation. Apply the blood pressure cuff around the patient’s arm. [Fig. 1] Press the F2 key [AUTO MANU] on the blood pressure measurement screen to bring up [MANUAL] on the display.
  • Page 39 13.Blood Pressure Measurement The pressure will begin to decrease once the optimal pressurization value is reached. [Fig. 5] * Once deflation has started, you can reinflate by pressing START (Start measurement) button. * If you wish to facilitate deflation after deflation has started, press the F1 key [DEFLATE].
  • Page 40: Ai Measurement

    14.AI Measurement 14.AI Measurement 14.1. AI Measurement This mode measures only AI. Attach the AI pulse wave sensor unit to the left wrist. (Refer to Section 9.2.) Check that the patient's name and ID appear in the upper-left part of the screen. [Fig. 1] If nothing is displayed, follow the instructions in Section 17.
  • Page 41 14.AI Measurement The applied pressure will become constant and a pulse wave will form in the upper-left part of the screen. Instruct the patient not to move while the measurement is in progress. Body movements and vibrations can cause a measurement error to occur.
  • Page 42 14.AI Measurement Press the [ ] buttons to display results from each measurement. Example: If 35 waveforms are measured: 34/35 35/35 1/35 2/35 The pulse wave number is displayed below the waveform (in the centre lower-left part of the screen). [Fig. 8] [Fig.
  • Page 43: Changing Magnification And Scroll Speed

    14.AI Measurement 14.2. Changing Magnification and Scroll Speed Changing the Continuous Pulse Wave Graph Magnification during AI Measurement: Press the ] keys to change the continuous pulse wave graph magnification. The default display is standard magnification [x1] The setting can be switched from among four options.
  • Page 44: Print

    15.Print 15.Print 15.1. Printing Measurement Results When [F6 PRINT] is displayed as a function key, you can print the contents of the screen by pressing the F6 key. You can print measurement results after each measurement is completed, or after retrieving the measurement results. Storing Printed Results If the printed results need to be stored for a long period of time, it is best to make and store a photocopy of the printout.
  • Page 45 15.Print Example: Print [AI AND BP MEASUREMENT] results [Fig. 2] Blood pressure: systolic value * When the BP value is manually input, [*] will be displayed. Blood pressure: Waveform diastolic value displayed on the screen Pulse pressure Date/time of measurement Pressure at peak of reflected wave AI value...
  • Page 46: Memory Retrieval

    16.Memory Retrieval 16.Memory Retrieval 16.1. Show All Data List It is possible to retrieve saved results. Also, trend graphs for each patient can be displayed and blood pressure measurement results can be added and modified. These functions can be used to manage data for a patient undergoing multiple examinations.
  • Page 47 16.Memory Retrieval Return to the pre-measurement screen. F1 key EXIT Enter the ID search screen. F2 key ID SEARCH Enter the ID replacement screen. F3 key REPLACE ID Display trend graphs. F4 key TREND GRAPH Enter the BP value edit screen. F5 key EDIT BP Delete data from database.
  • Page 48: Id Search

    16.Memory Retrieval 16.2. ID Search The registered ID numbers can be used to search for a specific patient’s measurement results. Press the F2 key [ID SEARCH] on the [DATABASE- ALL DATA-] screen. [Fig. 3] As a result, the ID search screen will be displayed. [Fig.4] [Fig.
  • Page 49: Delete Data

    16.Memory Retrieval 16.3. Delete Data Stored measurement results can be selected and deleted. Move the [ ] cursor to a data entry you wish to delete on the [DATABASE-ALL DATA-] or [DATABASE-PATIENT DATA-]. [Fig. 6] The total number of data entries and the current data number are displayed below the data list.
  • Page 50: Data Detail

    16.Memory Retrieval 16.4. Data Detail Displays patient’s detailed measurement results. On the [DATA BASE-ALL DATA-] or [PATIENT DATA] List screens, move the [ ] cursor to a data entry to access more detailed data from that measurement. [Fig. 8] The total number of data entries and the current data number displayed are shown in the lower left.
  • Page 51: Print Continuous Pulse Waves

    16.Memory Retrieval 16.5. Print Continuous Pulse Waves To print continuous pulse waves from patient’s detailed measurement results, follow the steps below. Continuous pulse waves can be printed only if pulse wave data is stored. (Refer to Section 18.7.) Press the F6 key on the [-DATA DETAIL-] screen. [Fig.
  • Page 52 16.Memory Retrieval Change the magnification and scroll speed on the preview screen if necessary. (Refer to Section 14.2.) Then press the F3 key [CONTINUOUS PULSE WAVE]. [Fig. 12] To stop printing before it has finished, press the F5 key [CANCEL PRINT]. The paper is fed and cut automatically.
  • Page 53: Trend Graph

    16.Memory Retrieval 16.6. Trend Graph Identifies trends within an individual patient’s multiple measurements. Press the F4 key [TREND GRAPH] on the [ALL 1 DAY DATA] or [PATIENT DATA] screens, or press the SET button on the [DETAILS] screen. A trend over a 1-day time will be displayed.
  • Page 54 16.Memory Retrieval F1 key EXIT Return to the pre-measurement screen. F2 key DATA LIST Return to the Data List screen. F4 key PATIENT DATA Return to the Patient Data List screen. Change the scale of the trend graph or select PRINT SBP F5 key SELECT GRAPH cb CONTRAST GRAPH...
  • Page 55: Adding And Modifying Blood Pressure Measurement Values

    16.Memory Retrieval 16.7. Adding and Modifying Blood Pressure Measurement Values It is possible to modify blood pressure measurement results from AI blood pressure measurements or add blood pressure measurement results to AI measurements. When F5 [EDIT BP] is displayed, it is possible to enter and modify blood pressure measurement values.
  • Page 56 16.Memory Retrieval To complete the entry, press the F2 key [YES]. If you do not want to save the data, press the F3 key [NO]. To return once again to the Manual Blood Pressure Entry screen, press the F1 key [CANCEL]. Once you have pressed the F2 [YES] or F3 [NO], you will be returned to the DATA BASE - ALL DATA.
  • Page 57: Registering Id Information

    17.Registering ID Information 17.Registering ID Information 17.1. ID Registration The patient’s [ID], [NAME], [BIRTH DATE], [GENDER] and [NOTES] can be registered in the ID information screen. [HEIGHT], [WEIGHT] and [NOTES] can be also added as measurement information. Once the patient’s ID information is registered, changes in the measurement results can be tracked continuously.
  • Page 58 17.Registering ID Information How to Enter Text Press the [ ] buttons to select the desired characters. Press the [ ] button to move the selector up. Press the [ ] button to move the selector down. Press the [ ] button to move the selector to the left.
  • Page 59 17.Registering ID Information How to Register a Birth Date [Fig. 6] Enter the month, day and year from the text selection box. [Fig. 6] The cursor will not move to the age field. [Fig. 7] After entering month, day and year and moving to the next field, the age will automatically be calculated based on the current date and the date of birth entered.
  • Page 60 17.Registering ID Information How to Register measurement information [Fig. 10] [HEIGHT], [WEIGHT] and [NOTES] can be entered as measurement information. You may change to either metric or English measurements as preferred. Refer to Section 18.5. for details. The cursor will not move to the BMI field. After entering height and weight and moving to the next field, the BMI will be automatically calculated based on the height and weight information entered.
  • Page 61: Retrieval / Edit Id

    17.Registering ID Information 17.2. Retrieval / Edit ID It is possible to use a patient’s ID to retrieve registration information if their registration is already complete. Press the F3 key [INPUT ID] on a screen where this button is displayed to enter the ID Input screen. [Fig.
  • Page 62 17.Registering ID Information Confirm the dialog if it appears and press the F2 key [SAVE] to register. [Fig. 16] The screen returns to Step 1, and the ID number will be shown on the upper-left part of the screen. [Fig. 16]...
  • Page 63: Replace Id

    17.Registering ID Information 17.3. Replace ID It is possible to select the saved measurement results and replace the ID number. Move the [ ] cursor to a data entry you wish to replace on the [DATABASE-ALL DATA-] or [DATABASE-PATIENT DATA-], and press the F3 key [REPLACE ID].
  • Page 64: Configuration Options

    18.Configuration Options 18.Configuration Options 18.1. How to Change the Settings The default settings are in the shaded boxes. SINGLE AVERAGE - 2 TIMES METHOD AVERAGE - 3 TIMES CHECK 0 min 3 min AVERAGE- INITIAL TIME 5 min MEASUREMENT 10 min 30 sec AVERAGE- 1 min...
  • Page 65 18.Configuration Options BRIGHTNESS DISPLAY 5 min DISPLAY/SOUND 15 min AUTO OFF TIMER 30 min 60 min DISABLE cm . kg HEIGHT/WEIGHT ft,in . lbs UNIT SOUND BEEP SOUND DATE DATE/TIME TIME 2005/12/31 (yyyy/mm/dd) 12-31-2005 DATE FORMAT DATE/TIME (mm-dd-yyyy) DISPLAY 31/12/2005 (dd/mm/yyyy) 12 hr.
  • Page 66: How To Change The Setup

    18.Configuration Options 18.2. How to Change the Setup You can change the HEM-9000AI’s initial setup according to your needs. Memory card ejection and initialization can also be performed under this setup process. Press the F5 key to enter the [SETUP] screen.
  • Page 67: How To Change The Measurement Settings

    18.Configuration Options 18.3. How to Change the Measurement Settings Blood pressure measurements, AI measurements, AI + blood pressure measurements and results printouts can be changed. Press the F5 key to enter the [SET UP] screen. (Refer to Section 18.2.) Move the [ ] cursor to [METHOD] under the [MENU] column and press the SET or [ ] button.
  • Page 68 18.Configuration Options To change the amount of time between blood pressure measurements. When selecting [AVERAGE - 2 TIMES] or [AVERAGE - 3 TIMES], it is possible to set the interval between blood pressure measurements. 1. Move the [ ] cursor to [AVERAGE - INTERVAL TIME]. [Fig.
  • Page 69 18.Configuration Options To change the [DISPLAY TONOGRAM] under [AI MEASUREMENT]: 1. Move the [ ] cursor to [DISPLAY TONOGRAM]. [Fig. 10] 2. Press the SET or [ ] button to move the [ ] cursor to [SETTING VALUE]. [Fig. 10] 3.
  • Page 70: How To Change Settings For Printing

    18.Configuration Options 18.4. How to Change Settings for Printing It is possible to change the content of data to be printed and saved. Press the F5 key to enter the [SET UP] screen. (Refer to Section 18.2.) Move the [ ] cursor to [PRINT] under the [MENU] column and press the SET or [ ] button to move the...
  • Page 71 18.Configuration Options To print a trend graph with measurement results: 1. Move the [ ] cursor to [PRINT TREND GRAPH]. 2. Press the SET or [ ] button to move the [ ] cursor to [SETTING VALUE]. [Fig. 6] 3. Move the [ ] cursor to the desired setting, selecting from [NO PRINT], [1 DAY TREND], [30 DAYS TREND] or [360 DAYS TREND] under [SETTING VALUE].
  • Page 72 18.Configuration Options To print measurement information with measurement results: What is measurement information includes the following. • Tonogram and measurement channel during measurement • Measurement time • Number of sampled pulse waves • Standard deviation of AI value • Pressure value of the AI pulse wave sensor during measurement [Fig.
  • Page 73 18.Configuration Options To select cSBP items to print on the trend graph: 1. Move the [ ] cursor to [cSBP PRINT ITEMS]. 2. Press the SET or [ ] button to move the [ ] cursor to [SETTING VALUE]. [Fig. 14] 3.
  • Page 74: How To Change Display/Sound Settings

    18.Configuration Options 18.5. How to Change Display/Sound Settings You can change the settings for the display and sound. Press the F5 key to enter the [SET UP] screen. (Refer to Section 18.2.) Move the [ ] cursor to [DISPLAY/SOUND] under the [MENU] column and press the SET or [ ] button to move the [...
  • Page 75 18.Configuration Options To change the [HEIGHT/WEIGHT UNIT] under [DISPLAY]: 1. Move the [ ] cursor to [HEIGHT/WEIGHT UNIT]. [Fig. 6] 2. Press the SET or [ ] button to move the [ ] cursor to [SETTING VALUE]. [Fig. 7] 3. Move the [ ] cursor to the desired setting, selecting [Fig.
  • Page 76: How To Change The Clock Settings

    18.Configuration Options 18.6. How to Change the Clock Settings It is possible to change the date and time settings and display. Press the F5 key to enter the [SET UP] screen. (Refer to Section 18.2.) Move the [ ] cursor to [DATE/TIME] under the [MENU] column and press the SET or [ button to move the [ ] cursor to [SETTING LIST].
  • Page 77: How To Change Settings For Storing

    18.Configuration Options 18.7. How to Change Settings for Storing Press the F5 key to enter the [SET UP] screen. (Refer to Section 18.1. for details on “How to Change the Settings”.) Move the [ ] cursor to [MEMORY CONTENTS] under the menu column and press the SET or [ ] button to move the [ ] cursor to [SETTING LIST].
  • Page 78: Returning To The Default Settings

    18.Configuration Options 18.8. Returning to the Default Settings It is possible to restore the system settings to the default settings. Hospital name will remain. Press the F5 key to enter the [SET UP] screen. (Refer to Section 18.2.) Move the [ ] cursor to [OTHER SETTINGS] under the [MENU] column and press the SET or [ ] button...
  • Page 79: Registering Hospital Name

    18.Configuration Options 18.9. Registering Hospital Name If a hospital name is registered, it is possible to store it with measurement results: The name will be printed with measurement results when it is stored. Press the F5 key to enter the [SET UP] screen. (Refer to Section 18.2.) Move the [ ] cursor to [OTHER SETTINGS] under...
  • Page 80: Memory Card

    18.Configuration Options 18.10.Memory Card If it becomes necessary to change the memory card once it becomes nearly full, it is possible to copy patient ID information that is already registered on the old card to a new card. Only the ID information will be copied. The measurement results will not be copied. Press the F5 key to enter the [SET UP] screen.
  • Page 81 (capacity 128MB). If PULSE WAVE DATA is ALL, the data for approximately 320 30 sec measurements can be saved. * Do not use any memory cards except those recommended by OMRON. 5. Press the F1 key [CANCEL] to return to the default screen.
  • Page 82: Keyboard

    18.Configuration Options 18.11.Keyboard A keyboard for the HEM-9000AI is sold separately. The keyboard offers the same functionality as the buttons in front of the main unit, or the character palette on the screen. How to connect the keyboard. Connect the keyboard to USB connector 1 or 2 on the back of the main unit.
  • Page 83: Calibration Measurement

    19.Calibration Measurement 19.Calibration Measurement It is recommended that you have the monitor inspected every two years to ensure it is accurate and functioning correctly. 19.1. How to Execute a Test Measurement You will need: (1) A mercury blood pressure monitor that is accurately adjusted (including a rubber bulb)*. (2) 2 T-tubes (3) 2 air tubes (4) Something to wrap a cuff around such as a sturdy tube (strong material that is not damaged or...
  • Page 84 (1) In the measuring rule, the test tolerance of blood pressure monitor (accuracy of pressure when shipped from the factory) should not exceed 3 mmHg. (2) If the CHECK result is +/- 3 mmHg or above, contact the dealer where you purchased this unit or OMRON.
  • Page 85: Introduction To Troubleshooting

    (3) Display “Out of Order, Do Not Use” on this device, and stop using the device. (4) Contact OMRON. The HEM-9000AI will identify several operator or user errors. As the display screen notifies users of errors, the errors will be categorized on screen as blood pressure measurement errors or AI errors.
  • Page 86: Error List

    21.Error List 21.Error List Error Codes for Blood Pressure Measurement Error Error Message on Error Name Error Content Action Display The cuff was not Required cuff pressure • Is the air tube connecting the inflated properly. was not achieved within cuff and the main unit loose? Inflation Error Blood pressure was...
  • Page 87 21.Error List Error Error Message on Error Name Error Content Action Display The reading was not accurately taken. An abnormal Blood The result of blood measurement value Pressure Error pressure was calculated. • Check for arrhythmia. Make measurement will sure that the patient does not not be displayed.
  • Page 88 AI pulse wave sensor unit. If this does not sensor unit cannot Disconnected. sensor unit. solve the problem, contact be detected. OMRON. Abnormality is AI Pulse Wave detected in the Sensor output of the AI Malfunction. pulse wave sensor unit.
  • Page 89 Flash ROM measurement unit measurement unit has power back on. If the problem is Aberration. malfunction. failed. not solved, contact OMRON. Measurement AI Pulse Wave started while the AI Measurement began • Follow the instructions for Sensor is pulse wave sensor while the AI pulse wave measurement preparation.
  • Page 90 21.Error List Error Error Message on Error Name Error Content Action Display • There is a possibility that the AI is less than 30% or larger than Measurement Detect an abnormal 150%. Confirm the measured Value The reading was not measurement value.
  • Page 91 Turn off the power. Reinsert the memory card and Current memory card cannot be used. turn the power back on. The number just entered was not appropriate. This value is out of range. Reenter the number. If the errors cannot be solved by the suggested actions, contact OMRON.
  • Page 92: Specifications

    22.Specifications 22.Specifications Name OMRON Non - Invasive Blood Pressure Monitor with Augmentation Index Model HEM-9000AI Power Supply AC100 V - 240 V 50/60 Hz 150 VA Electric Shock Protection Type Class I Operating Temperature and Humidity +10 - +40°C / 15 – 85% RH Storage Temperature and Humidity -20 - +60°C / 10 –...
  • Page 93 This medical device manufactured by OMRON Healthcare conforms to this IEC60601-1-2:2001 standard for both immunity and emissions. Nevertheless, special precautions need to be observed: •...
  • Page 94 22.Specifications...
  • Page 95 22.Specifications...
  • Page 96 OMRON HEALTHCARE UK LTD. Subsidiary Opal Drive Fox Milne, Milton Keynes MK 15 0DG, United Kingdom OMRON Medizintechnik Handelsgesellschaft m.b.H. Subsidiary Windeckstr. 81a, 68613 Mannheim, Germany www.omron-medizintechnik.de OMRON SANTÉ FRANCE SAS Subsidiary 14, rue de Lisbonne, 93561 Rosny-sous-Bois Cedex, France OMRON HEALTHCARE CO., LTD.

Table of Contents