Omron HEM-907 Instruction Manual
Omron HEM-907 Instruction Manual

Omron HEM-907 Instruction Manual

Digital automatic blood pressure monitor
Hide thumbs Also See for HEM-907:

Advertisement

Quick Links

INSTRUCTION MANUAL
OMRON
Digital Automatic Blood Pressure Monitor
Model
HEM-907
Thank you very much for purchasing the
OMRON Digital Automatic Blood Pressure
Monitor.
Instructions from OMRON to
the operators and the persons
responsible for maintenance.
Please read thoroughly the "Notes on Safety"
of this Instruction Manual before using this unit
so that you can use it safely and correctly after
After reading this Instruction Manual, please
keep it near the unit all the times for future
reference.

Table of Contents

Intended use ................................................. 2
Exemptions................................................... 3
Notes on Safety ............................................ 8
Components of the Product ....................... 12
Optional Medical Accessories ................... 12
Other Optional Parts .................................. 12
How to Apply the Arm Cuff......................... 13
(AC Adapter)........................................... 14
SINGLE Mode ........................................ 16
AVG. Mode ............................................. 17
MANU. Mode .......................................... 18
CHECK Mode ......................................... 19
Battery Pack ........................................... 20
List of Error Codes ..................................... 22
Troubleshooting .......................................... 23
............................................. 24
IM-HEM-907-E7-07-09/2022
5329412-4G
Issue Date / Fecha de publicación /
Uitgiftedatum / Data di pubblicazione /
Date de publication / Ausgabedatum:
2022-11-01
1

Advertisement

Table of Contents
loading

Summary of Contents for Omron HEM-907

  • Page 1: Table Of Contents

    Digital Automatic Blood Pressure Monitor Model HEM-907 Thank you very much for purchasing the Table of Contents OMRON Digital Automatic Blood Pressure Intended use ..........2 Monitor. Exemptions........... 3 Instructions from OMRON to Names and Functions of the Parts ....4 Notes on Safety ..........
  • Page 2: Intended Use

    Intended Use Medical Purpose This is a medical device that measures the brachial blood pressure in a non-invasive manner. Patient Population It is used on adult patients only. and other medical facilities. Precautions for use Warnings and cautions described in the instruction manual should be observed.
  • Page 3: Exemptions

    OMRON will not bear any responsibilities on the following matters. 1. When a problem or damage occurs caused by the maintenance and/or repair con- 2. The problem or damage of OMRON product caused by the product of other manu- facturer not delivered by OMRON 3.
  • Page 4: Names And Functions Of The Parts

    Names and Functions of the Parts Main unit 1. LCD display 6. ON/OFF (power) Button 2. HIDE (non-display) Button 7. START Button 8. DEFLATION control) Button 3. DC jack 9. Arm Cuff Connector 4. P-SET (pressure setting) Volume 10. STOP Button 5.
  • Page 5 Names and Functions of the Parts Ready to Measure Display Pulse level / Number of irregular pulse waves Number of irregular pulse waves: The pulse wave having a difference of more than ±25% from the average Systolic blood interval of pulse waves is determined pressure as irregular.
  • Page 6 Names and Functions of the Parts Explanation of Functions (1) Pressure setting function P - SET AUTO (automatic setting): In the SINGLE (single measurement), AVG. (average), and MANU. (auscultation) Modes, the Target value setting: systolic pressure. (2) Non-display function HIDE A function not to display the results of measured blood pressures.
  • Page 7 Names and Functions of the Parts (4) Setting mode change function You can set the number of times to measure, the waiting time until the start of measurement, and the interval between measurements. Items to set Set value Number of measurements 2 times, 3 times Waiting time until the start of measurement 0 sec, 3 min, 5 min, 10 min.
  • Page 8: Notes On Safety

    Notes on Safety • The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk and the damage to you and others from happening. •...
  • Page 9 Notes on Safety Caution When you are not going to use the unit for a long period of time, be sure to remove the AC adapter from the electric outlet. • Be sure to remove the AC adapter from the electric outlet when installing, removing, or cleaning the part. •...
  • Page 10 • Do not install or store the unit where it may be sprayed with water or medication. • You may suffer electric shock. Requests from OMRON • Do not place or put anything on the unit. • Do not apply strong shock to or drop the unit.
  • Page 11 2. Turn off the power and pull the AC adapter from the electric outlet. If an optional battery pack is used, remove it also. 3. Display “Trouble” on the unit so that it cannot be used. 4. Contact the dealer where you purchased the unit or the nearest OMRON dealer...
  • Page 12: Components Of The Product

    Applicable arm circumference: Applicable arm circumference: 32 to 42 cm 22 to 32 cm 17 to 22 cm Other Optional Parts (Contact the dealer where you purchased the unit or the nearest OMRON) Stand exclusive for this unit Wall-hanging kit Pole-mounting kit...
  • Page 13: How To Apply The Arm Cuff

    How to Apply the Arm Cuff Warning Requests from OMRON • Do not use the unit to the patient using a pump oxy- Do not apply the arm cuff during the intravenous genator. injection or transfusion. • • Intravenous injection or transfusion is impossible.
  • Page 14: How To Use The Power Source (Ac Adapter)

    • You may suffer electric shock. Requests from OMRON • If this unit is used concurrently with other unit, be sure to read the Instruction Manual of the other unit to be used concurrently and understand the warnings and cautions before use.
  • Page 15: How To Measure Blood Pressure

    You may suffer peripheral neuropathy. (2) When an error is generated or the measured value is doubtful Requests from OMRON · An error may be displayed when an external vibra- tion is applied or the patient moves his/her body. Be sure that the patient should not touch the unit.
  • Page 16 How to Measure Blood Pressure (in SINGLE Mode) 1. Wrap the arm cuff over the 2. Push the ON/OFF (power) patient’s arm. Button to turn on the power. ON/OFF START HIDE P-SET MODE SINGLE AVG. MANU. CHECK STOP AUTO 3. Set the MODE Selector to 4.
  • Page 17 How to Measure Blood Pressure (in AVG. Mode) 1. Wrap the arm cuff over the 2. Push the ON/OFF (power) patient’s arm. Button to turn on the power. ON/OFF START HIDE P-SET MODE SINGLE AVG. MANU. CHECK STOP AUTO 4. Set the P-SET (pressure set- 3.
  • Page 18 How to Measure Blood Pressure (in MANU. Mode) 1. Wrap the arm cuff over the 2. Place the stethoscope on the patient’s arm. patient’s arm. ON/OFF START HIDE P-SET MODE SINGLE AVG. MANU. CHECK STOP AUTO 4. Set the MODE Selector to 3.
  • Page 19 (1) In the measuring rule, the test tolerance of blood pressure monitor (accuracy of pressure when shipped from the factory) should not exceed 3 mmHg. (2) If the CHECK result is +/- 3 mmHg or above, contact the dealer where you purchased this unit or the nearest OMRON dealer.
  • Page 20: Installation And Replacement Of Battery Pack

    Installation and Replacement of Battery Pack Warning Caution Do not disassemble or modify the battery pack. Do not short the polarities of battery using metal object such as the wire. ment other than this unit. water. • rubbing the eye. Then immediately consult the doctor for treatment.
  • Page 21: How To Clean The Unit After Use

    How to Clean the Unit after Use Caution Requests from OMRON Pull the AC adapter from the electric outlet when • cleaning the unit. Do not clean the unit with gasoline, thinner, or high • You may suffer electric shock.
  • Page 22: List Of Error Codes

    Pule rate did not stay within the range of 30 to 199 beats/min. • Device error Contact the dealer where you purchased the unit or • There is a problem with the main unit of the the nearest OMRON dealer. blood pressure monitor.
  • Page 23: Troubleshooting

    Troubleshooting 30 cm. If the problem persists, please refer to the table below. Problem What to inspect How to correct Wrap the arm cuff correctly, and measure Is the arm cuff wrapped correctly? again. Ask the patient not to move his/her arm or Is the patient moving his/her arm or body body during measurement, and measure again.
  • Page 24 Product category Electronic Sphygmomanometers Product description OMRON Digital Automatic Blood Pressure Monitor Model (code) HEM-907 (HEM-907-E7) Display Digital display Measurement Oscillometric method Measurement Range Pressure; 0 to 299 mmHg Pulse rate; 30 to 199 beats/min Accuracy Pressure; Within +/-3 mmHg Pulse rate;...
  • Page 25 Degree of protection against Atmospheric pressure limitation electric shock (leakage current) Indication of connector polarity against electric shock CE Marking For indoor use only OMRON’s trademarked UKCA marking technology for blood pressure measurement Serial number the device Cuff positioning indicator for the...
  • Page 26 Need for the user to consult this Date of manufacture instruction manual. Need for the user to follow this Technology by OMRON instruction manual thoroughly for Healthcare in Japan your safety. Direct current Arm circumference...
  • Page 27 Manufacturer OMRON HEALTHCARE Co., Ltd. 53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com Importer in EU OMRON HEALTHCARE Co., Ltd. Matsusaka Factory Production facility 1855-370, Kubo-cho, Matsusaka-shi, Mie, 515-8503 Japan Importer in OMRON HEALTHCARE UK LTD.
  • Page 28 Further documentation in accordance with this EMC standard is available at OMRON HEALTHCARE EUROPE at the address mentioned in this instruction manual or at www.omron-healthcare.com Refer to the EMC information for HEM-907-E7 on the website. Correct Disposal of This Product (Waste Electrical & Electronic Equipment)

Table of Contents