Omron HEM907KIT Instruction Manual

Omron HEM907KIT Instruction Manual

Digital automatic blood pressure monitor

Advertisement

HEM-907-C3_D_M.fm Page 0 Wednesday, July 4, 2018 12:11 PM
OMRON
Digital Automatic Blood Pressure Monitor
HEM-907
Model
INSTRUCTION MANUAL
Thank you very much for purchasing the
OMRON Digital Automatic Blood Pressure
Monitor.
Please read this Instruction Manual thoroughly
to ensure safe and correct use of the monitor.
Please keep this Instruction Manual for future
reference.
HEM-907-C3_D_M04_180704.pdf

Table of Contents

Exemptions on warranty.....................1
Intended Use......................................2
Notes on Safety..................................3
Know Your Unit
Features of the Product......................7
Components of the Product ...............8
Other Optional Parts.......................9
Names of the Parts.......................10
while the unit is in use ..................12
Preparations before Measurement
How to Apply the Cuff ......................14
of Battery Pack .............................17
How to Measure Blood Pressure
SINGLE Mode ..............................19
AVG. Mode ...................................21
MANU. Mode ................................23
CHECK Mode ...............................25
List of Error Codes ...........................27
Troubleshooting ...............................28
(NIBP) Measurement .......................29
Specifications
Specifications ...................................30
MEMO (Blank pages).......................33
16
............

Advertisement

Table of Contents
loading

Summary of Contents for Omron HEM907KIT

  • Page 1: Table Of Contents

    HEM-907 Model INSTRUCTION MANUAL Table of Contents Thank you very much for purchasing the Be Sure to Read This Section OMRON Digital Automatic Blood Pressure Exemptions on warranty.....1 Monitor. Intended Use........2 Notes on Safety........3 Please read this Instruction Manual thoroughly Know Your Unit to ensure safe and correct use of the monitor.
  • Page 2: Be Sure To Read This Section Exemptions On Warranty

    1. When a trouble and/or damage occurs caused by the maintenance and/or repair conducted by a person other than OMRON or the dealer specified by OMRON 2. The trouble and/or damage of OMRON product caused by the product of other manufacturer not delivered by OMRON 3.
  • Page 3: Intended Use

    The instrument is used in physicians' offices, hospitals, clinics and other medical facilities. Durable Period 5 years, provided that the appropriate maintenance has been done from production date. (Self-certification through OMRON HEALTHCARE's own data) ■ Non-invasive Blood Pressure Measurement Parameter ■ Pulse rate Precautions for use Warnings and cautions described in the instruction manual should be observed.
  • Page 4: Notes On Safety

    HEM-907-C3_D_M.fm Page 3 Wednesday, July 4, 2018 12:11 PM Notes on Safety • The warning signs and the sample icons shown here are listed for you to use the product safely and correctly as well as to prevent the risk and the damage to you and others from happening. •...
  • Page 5 HEM-907-C3_D_M.fm Page 4 Wednesday, July 4, 2018 12:11 PM Notes on Safety Caution In the following cases, check the readings with the stethoscope. (1) When an irregular pulse wave is displayed • The reading may be erroneous due to external vibration or patient's body movement. (2) When erroneous reading takes place or the measured value is doubtful •...
  • Page 6 HEM-907-C3_D_M.fm Page 5 Wednesday, July 4, 2018 12:11 PM Notes on Safety Caution During measurement, make sure that no mobile phone or any other electrical units that emit electromagnetic fields is within 30 cm of this monitor. • It may result in incorrect operation of the monitor and/or cause an inaccurate reading. Do not use this unit in a moving vehicle.
  • Page 7 2. Turn off the power and pull the AC adapter from the electric outlet. If an optional battery pack is used, remove it also. 3. Display “Trouble” on the unit so that it cannot be used. 4. Contact the dealer where you purchased the unit or the nearest OMRON dealer Disposal...
  • Page 8: Features Of The Product

    INTELLISENSE blood pressure monitor is a global brand name of blood pressure monitor equipped with bio-information sensing and high performance fuzzy logic technology, which are the key technologies of OMRON. With this excellent sensing technology, the monitor can achieve "accurate measurement".
  • Page 9: Components Of The Product

    HEM-907-C3_D_M.fm Page 8 Wednesday, July 4, 2018 12:11 PM Components of the Product Main unit Accessories Cuff / bladder set M (with built-in bladder)* Air tube 1.0 m (39 1/3") Model:HEM-CR19 Model: HEM-TUBE-100 Applicable arm circumference: 22 to 32 cm AC adapter Instruction Manual Model: SA1306-080070AU...
  • Page 10: Optional Medical Accessories

    HEM-907-C3_D_M.fm Page 9 Wednesday, July 4, 2018 12:11 PM Components of the Product Optional Medical Accessories (within the scope of EC Medical Device Directive 93/42/EEC) Air tube 1.3 m * Air tube 1.0 m * Model: HEM-TUBE-130CE Model: HEM-TUBE-100CE Other Optional Parts Cuff cloth (three types) * Bladder (three types) * Battery pack *...
  • Page 11: Names And Functions Of The Parts

    HEM-907-C3_D_M.fm Page 10 Wednesday, July 4, 2018 12:11 PM Names and Functions of the Parts Names of the Parts Main unit 1. Display 6. ON/OFF (power) Button 2. HIDE (non-display) Button 7. START Button (to start measurement) 8. DEFLATION (deflation control) /Display Switch Button 3.
  • Page 12 HEM-907-C3_D_M.fm Page 11 Wednesday, July 4, 2018 12:11 PM Names and Functions of the Parts Display Systolic blood pressure When the measurement is finished: Displays systolic blood pressure. When an error occurred: Displays error code. In the CHECK Mode: Displays pressures. Diastolic blood pressure Ready to Measure / During measurement: Displays pressures.
  • Page 13: Functions And Setting While The Unit Is In Use

    HEM-907-C3_D_M.fm Page 12 Wednesday, July 4, 2018 12:11 PM Names and Functions of the Parts Functions and setting while the unit is in use (1) Pressure setting function P - SET A function that can switch the pressure setting Inflation can be set by AUTO (automatic setting) method or the pressure value setting method. AUTO (Automatic setting): Can be used when the SINGLE, AVG., or MANU.
  • Page 14 HEM-907-C3_D_M.fm Page 13 Wednesday, July 4, 2018 12:11 PM Names and Functions of the Parts List of Functions for each Mode Measurement Single Average Auscultation Check Mode measurement (AVG.) (MANU.) (CHECK) Function (SINGLE) Pressure setting function Non-display function Manual deflation control function (4) Function setting You can set the number of measurements, the waiting time until the start of 1st measurement, and...
  • Page 15: How To Apply The Cuff

    HEM-907-C3_D_M.fm Page 14 Wednesday, July 4, 2018 12:11 PM How to Apply the Cuff The cuff of OMRON Digital Automatic Blood Pressure Monitor HEM-907 plays an important role of collecting the information on blood vessels. Please wrap the cuff correctly according to the procedure.
  • Page 16 HEM-907-C3_D_M.fm Page 15 Wednesday, July 4, 2018 12:11 PM How to Apply the Cuff 4. Place the right hand of the patient with the palm of hand facing upward. 5. Align the Artery Position Mark with the brachial artery. 6. Wrap the cuff snugly using both hands and securely fasten it with the Velcro tape.
  • Page 17: How To Use The Power Source

    HEM-907-C3_D_M.fm Page 16 Wednesday, July 4, 2018 12:11 PM How to Use the Power Source How to use the AC adapter Warning Caution Do not use this unit in places where Be sure to use the AC adapter appropriate for inflammable gas, such as highly inflammable your country.
  • Page 18: Installation And Replacement Of Battery Pack

    HEM-907-C3_D_M.fm Page 17 Wednesday, July 4, 2018 12:11 PM How to Use the Power Source Installation and Replacement of Battery Pack (option) Warning Caution If the fluid in the battery gets into your eye, Do not short-circuit the polarities of the wash the eye with sufficient water without optional battery pack with a metal object such rubbing the eye, then immediately consult the...
  • Page 19: How To Measure Blood Pressure

    HEM-907-C3_D_M.fm Page 18 Wednesday, July 4, 2018 12:11 PM How to Measure Blood Pressure Warning Caution If any abnormal matter occurs during the In the following cases, check the readings with measurement such as inflation does not stop, the stethoscope. remove the cuff or pull out the air tube from the (1) When an irregular pulse wave is displayed main unit.
  • Page 20 HEM-907-C3_D_M.fm Page 19 Wednesday, July 4, 2018 12:11 PM How to Measure Blood Pressure (in SINGLE Mode) 1. Push the ON/OFF (power) Button to turn on the power. ON/OFF START HIDE P - SET MODE SINGLE AVG. MANU. CHECK STOP AUTO 2.
  • Page 21 HEM-907-C3_D_M.fm Page 20 Wednesday, July 4, 2018 12:11 PM How to Measure Blood Pressure (in SINGLE Mode) 5. Push the START Button to start the measurement. mmHg • Do not push the ON/OFF START Button without ON/OFF wrapping the cuff on START START HIDE...
  • Page 22 HEM-907-C3_D_M.fm Page 21 Wednesday, July 4, 2018 12:11 PM How to Measure Blood Pressure (in AVG. Mode) 1. Push the ON/OFF (power) Button to turn on the power. ON/OFF START HIDE P - SET MODE SINGLE AVG. MANU. CHECK STOP AUTO 2.
  • Page 23 HEM-907-C3_D_M.fm Page 22 Wednesday, July 4, 2018 12:11 PM How to Measure Blood Pressure (in AVG. Mode) 5. Push the START Button to start the measurement. The unit automatically starts measurement according to the mmHg ON/OFF waiting time until the start of 1st measurement. After displaying the results of 1st measurement, the monitor will measure blood pressure for the set number of times START...
  • Page 24 HEM-907-C3_D_M.fm Page 23 Wednesday, July 4, 2018 12:11 PM How to Measure Blood Pressure (in MANU. Mode) 1. Push the ON/OFF (power) Button to turn on the power. ON/OFF START HIDE P - SET MODE SINGLE AVG. MANU. CHECK STOP AUTO 2.
  • Page 25 HEM-907-C3_D_M.fm Page 24 Wednesday, July 4, 2018 12:11 PM How to Measure Blood Pressure (in MANU. Mode) 5. Place the stethoscope on the patient's arm. ON/OFF START HIDE P-SET MODE SINGLE AVG. MANU. CHECK STOP AUTO 6. Push the START Button to start the measurement.
  • Page 26: Check Mode

    (1) Generally, the test tolerance of blood pressure monitor (accuracy of pressure when shipped from the factory) should not exceed 4 mmHg. (2) If the CHECK result shows a difference of +/- 5 mmHg or more, contact the store where you purchased this unit or the nearest OMRON dealer.
  • Page 27: How To Clean The Unit After Use

    HEM-907-C3_D_M.fm Page 26 Wednesday, July 4, 2018 12:11 PM How to Clean the Unit after Use Caution General advice When cleaning this unit, please unplug the AC • Do not clean this unit with gasoline, paint thinner, or adapter from the electric outlet. high concentration alcohol.
  • Page 28: List Of Error Codes

    • Pulse rate is not within the range of 30 to 199 beats/min. Device error • Contact the store where you purchased this mon- • This is an indication of trouble of the main itor or the nearest OMRON dealer. unit.
  • Page 29: Troubleshooting

    HEM-907-C3_D_M.fm Page 28 Wednesday, July 4, 2018 12:11 PM Troubleshooting In case any of the below problems occur during use, first check that no other electrical unit is within 30 cm. If the problem persists, please refer to the table below. Trouble What to inspect How to correct...
  • Page 30: Non-Invasive Blood Pressure (Nibp) Measurement

    HEM-907-C3_D_M.fm Page 29 Wednesday, July 4, 2018 12:11 PM Non-Invasive Blood Pressure (NIBP) Measurement Non-Invasive Pressure Measurement Principles Oscillometric method The beat in the pulsation generated by the contraction of the heart is captured as the pressure inside the cuff to measure the blood pressure.
  • Page 31: Specifications

    HEM-907-C3_D_M.fm Page 30 Wednesday, July 4, 2018 12:11 PM Specifications Name: OMRON Digital Automatic Blood Pressure Monitor Model: HEM-907 Display: Digital display Measurement: Oscillometric method Measurement Range: Pressure; 0 to 299 mmHg Pulse rate; 30 to 199 beats/min Accuracy: Pressure; Within ±3 mmHg Pulse rate;...
  • Page 32 HEM-907-C3_D_M.fm Page 31 Wednesday, July 4, 2018 12:11 PM Specifications Symbols description Applied part - Type BF OMRON’s trademarked Degree of protection against technology for blood electric shock (leakage pressure measurement current) Class II equipment. Identifier of cuffs compatible Protection against electric...
  • Page 33 Depending on the product, some of the above symbols may not be applicable on the product. Important information regarding Electro Magnetic Compatibility (EMC) HEM-907 manufactured by OMRON HEALTHCARE Co., Ltd. conforms to EN60601-1-2:2015 Electro Magnetic Compatibility (EMC) standard. Further documentation in accordance with this EMC standard is available at http://www.omronhealthcare-ap.com/emc-information.
  • Page 34: Memo (Blank

    HEM-907-C3_D_M.fm Page 33 Wednesday, July 4, 2018 12:11 PM MEMO...
  • Page 35 HEM-907-C3_D_M.fm Page 34 Wednesday, July 4, 2018 12:11 PM MEMO...
  • Page 36 53, Kunotsubo, Terado-cho, Muko, KYOTO, 617-0002 JAPAN EU-representative OMRON HEALTHCARE EUROPE B.V. Scourpius 33, 2132 LR Hoofddorp, THE NETHERLANDS www.omron-healthcare.com OMRON HEALTHACARE SINGAPORE PTE LTD. 438A Alexandra Road, #05-05/08, Alexandra Technopark, Singapore Asia Pacific HQ 119967 www.omronhealthcare-ap.com OMRON HEALTHCARE Co., Ltd.

This manual is also suitable for:

Hem-907

Table of Contents