Configuring Remote Management Access - NETGEAR STM150 Appliance Reference Manual

Prosecure web/email security threat management (stm)
Hide thumbs Also See for STM150:
Table of Contents

Advertisement

ProSecure Web/Email Security Threat Management (STM) Appliance Reference Manual
Table 3-4. Set Password Settings screen; Administrator and Guest Settings (continued)
Setting
New Password
Retype New Password Confirm the new password.
3. Under the Administrator Settings and Guest Settings sections of the screen, click Apply to
save your settings.
4. If you modified the administrator settings and now want to modify the guest settings, or the
other way around, repeat
5. To modify the Web Management Interface timeout settings, complete the field as explained in
Table
3-5.
Table 3-5. Set Password Settings screen: Web Interface Timeout Settings
Setting
Web Interface Timeout
Session Timeout
6. Under the Web Interface Timeout section of the screen, click Apply to save your settings.
Note: After a factory default reset, the password and timeout value are changed back to
password and 600 seconds (5 minutes), respectively.

Configuring Remote Management Access

An administrator can configure, upgrade, and check the status of the STM over the Internet via a
Secure Sockets Layer (SSL) VPN connection.
You must use an SSL VPN connection to access the STM from the Internet. You must enter
https:// (not http://) and type the STM's WAN IP address into your browser. .For example, if the
STM's WAN IP address is 172.16.0.123, type the following in your browser: https://172.16.0.123.
The STM's remote login URL is:
Performing Network and System Management
Description (or Subfield and Description)
Enter the new password.
step 2
and
step 3
for the other settings.
Description (or Subfield and Description)
Enter the period in seconds after which the Web Management Interface is
automatically logged off if no activity is detected. The default is 600 seconds.
The maximum period that you can configure is 9999 seconds. To disable
session timeout entirely so that the Web Management Interface is never
logged off because of inactivity, enter 0.
v1.0, September 2009