Dialer Programming (*40 - *52) - ADEMCO Vista-15 Installation And Setup Manual

Hide thumbs Also See for Vista-15:
Table of Contents

Advertisement

FIELD
TITLE and DATA ENTRIES
Exit Delay 2
*36
0 = 30-second delay
1 = 45-second delay
2 = 60-second delay
3 = 90-second delay
Audible Exit Warning
*37
0 = no exit warning sound
1 = provide exit warning sound when armed AWAY
or MAXIMUM
Confirmation Of Arming Ding
*38
0 = no ding
1 = confirmation ding after arming system
2 = confirmation ding after arming from RF button
or RF keypad only (ding occurs when the system
receives the RF transmission)
Power Up In Previous State
*39
0 = always power up in a disarmed state
1 = assume the system status prior to power-down

Dialer Programming (*40 - *52)

FIELD
TITLE and DATA ENTRIES
NOTE: Fields ✱ 40, ✱ 41, ✱ 42:
Enter up to the number of digits shown. Do not fill unused spaces. Enter 0–9, # + 11 for ✱ # + 12 for # # + 13 for a pause (2 seconds)
Pabx Access Code
*40
Enter up to 6 digits if PABX is needed to access an
outside line.
Primary Phone No.
*41
Enter up to 20 digits.
Secondary Phone No.
*42
NOTE: For Fields •43 and •44:
Enter digits 0–9; # +11=B; # +12=C; # +13=D; # +14=E; or # +15=F.
Enter [•] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first digit of a 4-digit account
number for Nos. 0000-0999. Exit field by pressing ✱ (and press next field number) if only 3 digits are used.
To clear entries from field, press ✱ 43 ✱ or ✱ 44 ✱ . See separate Programming Form for examples of account number entries.
Primary Subs Account No.
*43
Secondary Subs Account No.
*44
Phone System Select
*45
If Central Station receiver is not on WATS line:
0 = pulse dial
1 = tone dial
If Central Station receiver is on WATS line:
2 = pulse dial
3 = tone dial
4 = 120-second delay
5 = 180-second delay
6 = 240-second delay
EXPLANATION
The system waits the time entered before it sounds an alarm upon
entering.
UL installations: Must be set for a maximum of 45 seconds
Warning sound consists of slow continuous beeps until last 10 seconds,
when it changes to fast beeps. The warning sound ends at the
termination of Exit time.
Confirmation of arming is ½-second external sounder "ding" when closing
report is sent, or at the end of Exit Delay.
When the system powers up armed, an alarm occurs 1 minute after
arming if a zone is faulted.
Note that if the previous state was armed AWAY, STAY, NIGHT-STAY,
INSTANT, or MAXIMUM, the system does not respond to sensor
changes for 1 minute, which allows time for sensors such as PIRs to
stabilize.
UL installations: Must be 1 (power up in previous state).
EXPLANATION
If fewer than 6 digits need to be entered, exit by pressing [•] and next
field number (e.g.,41). To clear entries from field
If you enter fewer than 20 digits, exit by pressing [ ✱ ] and next field
number (e.g., 42). To clear entries from field, press ✱ 41 ✱ .
NOTE: Backup reporting (in which 8 calls are made to the secondary
phone number if no kissoff is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number (field
✱ 42).
Enter up to 20 digits. If you enter fewer than 20 digits, exit by pressing
[•]•and next field number (e.g., 43). To clear entries from field, press
•42•. See backup reporting note for field •41. If using the pager feature,
enter the pager phone number here.•
Section 5 - Data Field Programming
,
press *40 *.
5–3