Confirmation Of Arming Ding
*38
Entry 1: 0 = no; 1 = yes, 1-second ding
(ding if armed from wired keypad)
Entry 2: Enter 0-15 from table below.
(ding if armed from RF device)
Entry
Ding at Siren Trigger 2 Output
0
none
none
1
none
250mS
2
none
1 second
3
none
4 seconds
4
250mS
none
5
250mS
250mS
6
250mS
1 second
7
250mS
4 seconds
8
1 second
none
9
1 second
250mS
#+10
1 second
1 second
#+11
1 second
4 seconds
#+12
4 seconds
none
#+13
4 seconds
250mS
#+14
4 seconds
1 second
#+15
4 seconds
4 seconds
Power-Up In Previous State
*39
0 = always power-up in a disarmed state
1 = assume the system status prior to
power down
Dialer Programming ( 40 – 50)
FIELD
TITLE and DATA ENTRIES
PABX Access Code
*40
Enter up to 6 digits if PABX is needed to
access an outside line. Do not fill unused
spaces.
0–9, # + 11 for '', # + 12 for '#', # + 13 for a
pause (2 seconds)
Primary Phone No.
*41
Enter up to 20 digits. Do not fill unused
spaces.
0–9, # + 11 for '', # + 12 for '#', # + 13 for a
pause (2 seconds)
Secondary Phone No.
*42
Enter up to 20 digits.
0–9, # + 11 for ' ', # + 12 for '#', # + 13 for a
pause (2 seconds)
Part. 1 Primary Subs. Acct. No.
*43
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 1 Secondary Subs. Acct.
*44
No.
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Primary Subs. Acct. No.
*45
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Secondary Subs. Acct. No.
*46
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Entry 1 for each partition selects whether arming from wired
keypads causes siren ding. Confirmation of arming is 1/2 second
external sounder "ding." Ding occurs when closing reports is sent, or
when exit delay expires.
Entry 2 for each partition selects whether arming from remote RF
devices causes siren ding and/or activates trigger 2 output; also selects
siren ding/trigger activation duration (arm = 2 dings of selected
duration with 1 second off between; disarm = 1 ding of selected
duration). Ding occurs upon reception of the wireless arming command.
NOTE: If using an option that activates trigger 2, trigger 2 must be
dedicated to only this function; do not assign any other functions to
trigger 2.
When the system powers up armed, an alarm will occur 1 minute
after arming if a zone is faulted at that time.
Note that if the previous state was armed AWAY or STAY, the
system will not respond to sensor changes for 1 minute, which allows
time for sensors such as PIRs to stabilize.
EXPLANATION
To clear entries from field, press 40. If fewer than 6 digits need to
be entered, exit by pressing [], which advances to the next field.
Call Waiting: If the subscriber's phone service has "call waiting"
(and is not using PABX), enter "*70" ("# + 11") plus "# + 13" (pause)
as the PABX entry to disable "call waiting" during control panel calls.
If the subscriber does not have "call waiting" and is not using PABX,
make no entry in this field.
If you enter fewer than 20 digits, exit by pressing []. To clear entries
from field, press 41.
NOTE: Backup reporting (in which 8 calls are made to the secondary
phone number if no kissoff is received after 8 attempts to the primary
number) is automatic only if there is a secondary phone number (field
42).
If you enter fewer than 20 digits, exit by pressing []. To clear entries
from field, press 42. See backup reporting note for field 41.
Don't fill unused spaces.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press 43.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press 44.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press 45.
Enter up to 10 digits, depending on the report format selected in field
*48. To clear entries from field, press 46.
4-3