VISTA-15/VISTA-15CN Installation and Setup Guide
(With Verification on
Only hardwired zone 1 can be programmed as a fire zone in UL installations. However, any wireless zone can be used as a
fire zone.
No Alarm Response
All of the zone types described are available for the wireless portion of the system, if used.
The reaction of a zone type is changed if the zone itself is included in either Zone List 04 or Zone List 05. See Section
18. Zone Lists for further explanation.
4–2
Type 08
This zone type sends a report to Central Station and provides an alarm sound at the
keypad. (No bell output is provided). This zone type is usually assigned to a zone
24-hour
containing a button for use in personal emergencies, or to a zone containing monitoring
Auxiliary Alarm
devices such as water or temperature sensors.
Type 09
This zone type provides a fire alarm on short circuit and a trouble condition on open
circuit. The bell output pulses when this zone type is alarmed. This zone type is always
Supervised Fire
active and cannot be bypassed. This zone type can be assigned to a hardwired zone,
any zone in a wired zone Expansion Module, or wireless zones. When used with zone 1
Zone 1)
on the panel, 2-wire smoke detectors can be used.
This zone type gives Entry Delay (using the programmed entry time), if tripped when the
Type 10
panel is armed in the AWAY mode. Entry Delay begins whenever sensors in this zone
Interior w/Delay
are violated, regardless of whether or not an Entry/Exit Delay zone was tripped first. No
Entry Delay is provided if tripped when the panel is armed in the MAXIMUM mode. Exit
Delay is present for any arming mode. This zone type is bypassed when the panel is
armed in the STAY or INSTANT mode. If the panel is armed NIGHT-STAY, this zone
type is not bypassed if it is on the NIGHT-STAY Zone List 05.
Type 12
This zone type is a dynamic monitor of a zone fault/trouble. In the case of a short/open,
the message, "*ALARM*-24 Hr. Non-Burg. -#XXX " (where XXX is the zone number) is
24 Hour Monitor
sent to the Central Station. The system keypad displays a fault message indicating the
appropriate zone. Upon restoral of the zone, the message, "*RESTORE*-24 Hr. Non-
Burg. -#XXX " is sent to the Central Station. The fault message automatically
disappears from the keypad. The zone restores dynamically; therefore, a User Code +
OFF sequence is not needed to reset the zone. Faults of this zone type are independent
of the system, and can exist at the time of arming without interference.
If you want to use this zone type to activate a relay, all zones of Type 12 must be placed
into a zone list and triggered by a "fault" event. The same zone list must be programmed
for the "STOP" event. A restore of every faulted zone in that zone list is required to
deactivate the relay.
Type 20
This is a special-purpose zone type, used with 5800 Series Wireless Pushbutton units,
which results in arming the system in the STAY mode when the zone is activated.
Arm-STAY
Pushbutton units send the zone number as a user number to the Central Station when
arming or disarming.
Type 21
This is a special-purpose zone type, used with 5800 Series Wireless Pushbutton units,
which results in arming the system in the AWAY mode when the zone is activated.
Arm-AWAY
Pushbutton units send the zone number as a user number to the Central Station when
arming or disarming.
This is a special-purpose zone type, used with 5800 Series Wireless Pushbutton units,
Type 22
which results in disarming the system when the zone is activated.
Disarm
Type 23
This zone type can be used on a zone when an output relay action is desired, but with
no accompanying alarm (e.g., lobby door access).
Type 24
This zone type provides an instant alarm, with no audible indication at any keypad or
external sounder, if the zone is faulted when the system is armed in the AWAY, STAY,
Silent Burglary
NIGHT-STAY, INSTANT, or MAXIMUM mode. This zone type is usually assigned to all
sensors or contacts on exterior doors and windows where bells and/or sirens are NOT
desired. A report is sent to the Central Station.