VISTA-15/VISTA-15CN Installation and Setup Guide
FIELD
TITLE and DATA ENTRIES
Option Selection (Audio Alarm Verification)
*91
0 = not using AAV
4 = an Audio Alarm Verification (AAV) unit is
connected to the system
8 = enable Exit Delay Restart (Quick Exit)
12 = both AAV and Exit Delay Restart
Phone Line Monitor Enable
*92
0 = not used
1 = local keypad display only when phone line is
faulted
2 =local keypad display plus keypad trouble
sound when line is faulted; no automatic timeout
3 =same as "2" above plus Device No. 2 STARTS;
if system is armed, external sounder activates;
external sounder is turned off by normal bell
timeout, or by entering Security Code + OFF.
Swinger Suppression
*93
0 =Unlimited, 1-15 = Number of alarms (1-9; #
+10 = 10; # +11 = 11; # +12 = 12; # +13 = 13; #
+14 = 14; # +15 = 15
5–10
EXPLANATION
UL installations: Must be 0 (AAV disabled).
NOTES:
•Option 3 may be used even if a relay unit or Powerline Carrier device is
not connected to the control.
•Device number 2 must either be programmed to be STOPPED in field
✱ 80 or STOPPED by entry of Security Code + # + 8 + 2. Field ✱ 80
should be set to 0 for STOP.
This feature does not function properly unless the designated earth
ground terminal (25) is physically connected to earth ground. If it is not,
you may get false line-cut indications.
This option can be used to limit the number of messages (Alarm and
Alarm Restore reports) sent to the Central Station in an armed period.
UL installations: Must be set to 0 (unlimited reports).