Dialer Programming ( ∗ 40 - ∗ 50) - ADEMCO VISTA-20P Installation And Setup Manual

Hide thumbs Also See for VISTA-20P:
Table of Contents

Advertisement

Dialer Programming ( ∗ 40 – ∗ 50)
FIELD
TITLE and DATA ENTRIES
Primary Phone No.
*41
Enter up to 20 digits. Do not fill unused
spaces.
0–9, # + 11 for '∗', # + 12 for '#', # + 13 for a
pause (2 seconds)
Secondary Phone No.
*42
Enter up to 20 digits. Do not fill unused
spaces.
0–9, # + 11 for ' ✱ ', # + 12 for '#', # + 13 for a
pause (2 seconds)
Part. 1 Primary Subs. Acct. No.
*43
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 1 Secondary Subs. Acct. No.
*44
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Primary Subs. Acct. No.
*45
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Part. 2 Secondary Subs. Acct. No.
*46
Enter digits 0–9; # + 11 for B, # + 12 for C, #
+ 13 for D, # + 14 for E, # + 15 for F.
Phone System Select
*47
If Central Station Receiver is not on WATS
line: 0 = Pulse Dial; 1 = Tone Dial
If Central Station Receiver is on WATS line:
2 = Pulse Dial; 3 = Tone Dial
Report Format
*48
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
6 = 4+2 ADEMCO EXPRESS
7 = ADEMCO CONTACT ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
Split/Dual Reporting
*49
0 = disable (Backup report only).
1 - 5 (see table to right)
15-Second Dialer Delay (Burglary)
*50
0 = no dialer delay
1 = 15-second delay
SESCOA/Radionics Select
*53
0 = Radionics (0-9, B-F reporting)
1 = SESCOA (0-9 only reporting)
EXPLANATION
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number (e.g., 42). To clear entries from field, press ∗41∗.
NOTE: Backup reporting (in which 8 calls are made to the secondary
phone number if no kissoff is received after 8 attempts to the
primary number) is automatic only if there is a secondary phone
number (field ∗42).
If you enter fewer than 20 digits, exit by pressing [∗] and next field
number (e.g., 43). To clear entries from field, press ∗42∗. See backup
reporting note for field ∗41.
To clear entries from field, press ∗43∗.
To clear entries from field, press ∗44∗.
VISTA-20P only.
To clear entries from field, press ∗45∗.
VISTA-20P only.
To clear entries from field, press ∗46∗.
Select the type of telephone service.
Select report format for primary and secondary phone numbers.
(Primary/Secondary)
1 = alarms, restore, cancel
2 = all except open/close, test
3 = alarms, restore, cancel
4 = all except open/close, test
5 = all
Provides delay of "BURGLARY ALARM" report to the central
station, which allows time for the subscriber to avoid a false alarm
transmission. This delay does not apply to zone type 24 alarms,
which are always sent as soon as they occur.
UL installations must be 0 (no delay).
Select SESCOA or Radionics format.
Select 0 for all other formats.
To Primary No.
To Secondary No.
others
open/close, test
all
all
all
4-3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-20pcnVista-15pVista-15pcn