ADEMCO Vista-15 Installation And Setup Manual page 80

Hide thumbs Also See for Vista-15:
Table of Contents

Advertisement

VISTA-15/VISTA-15CN Installation and Setup Guide
6128 REMOTE KEYPAD
1. Physical:
2. Electrical:
3. Interface Wiring:
6128RF INTEGRATED KEYPAD
1. Physical:
2. Electrical:
3. Interface Wiring:
6139 REMOTE KEYPAD
1. Physical:
2. Electrical:
3. Interface Wiring:
5881/5882 SERIES RF RECEIVERS (5800 System)
1. Physical:
2. Electrical:
3. Interface Wiring:
4. Range:
5. Zones:
5800TM TRANSMITTER MODULE (used with 5827BD Wireless 2-Way Keypad)
1. Physical:
2. Electrical:
3. Interface Wiring:
4204 RELAY MODULE
1. Physical:
2. Electrical:
3. Interface Wiring:
4. Four Output Relays:
4219 WIRED EXPANSION MODULE
1. Physical:
2. Electrical:
3. Interface Wiring:
4. 8 EOLR Loops (A–H):
15–2
5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 25mm)
Voltage Input: 12VDC; Current Drain: 30mA
To control panel's keypad connection points.
RED:
12VDC input (+) aux pwr
GREEN:
Data to Control Panel (DO)
YELLOW:
Data from Control Panel (DI)
BLACK:
Ground
5-3/4" W x 4-3/4" H x 1" D (146mm x 121mm x 25mm)
Standby: 90mA
Transmitting and/or relay activated: 120mA
Relay Contact: N/O, 1A, 28VDC
Same as 6128 Remote Keypad above.
6-1/4" W x 4-3/4" H x 1" D (159mm x 121mm x 25mm)
Voltage Input: 12VDC; Current Drain: 100mA
Same as 6128 Remote Keypad above.
7-3/8" (187mm) W x 4-3/8" (111mm) H x 1-7/16" (37mm) D
Note: 10-7/8" (277mm) H with antenna
Voltage Input: 12VDC; Current Drain:
To control panel's keypad connection points.
200ft (60m) nominal indoors from wireless transmitters (the actual
range to be determined with system in Test mode).
( With the ADEMCO VISTA-15/VISTA-15CN )
5881L/5882L: accepts up to 8 transmitters
5881M/5882M: accepts up to 16 transmitters
5881H/5882H: accepts up to 26 transmitters
2-1/4" W x 4-1/8" H x 7/8" D (57mm x 105mm x 22mm)
Voltage Input: 12VDC; Current Drain: 20mA
To control panel's keypad connection points.
6-1/2" W x 4-1/4" H x 1-1/4" D (169mm x 108mm x 32mm)
Voltage Input: 12VDC; Current Drain: 15mA (Relays off) 180mA
To control panel's keypad connection points.
SPDT Contacts, Rating: 2A max at 28VDC/AC
6-1/2" W x 4-1/4" H x 1-1/4" D (169mm x 108mm x 32mm)
Voltage Input: 12VDC; Current Drain: 35mA
To control panel's keypad connection points.
Loop A can be set for fast (10-15mSec) response to an open.
(Relays on)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vista-15cn

Table of Contents