VISTA-15/VISTA-15CN Installation and Setup Guide
If you want to use zone type 12, 24-Hour Monitor, to activate a relay, all zones of that type must be
placed into a zone list and triggered by a "fault" event. The same zone list must be programmed for the
"STOP" event. A restore of every faulted zone in that zone list is required to deactivate the relay.
7–4
To program the above example, do the following:
✱
1.
In
80 Interactive mode, choose Output Device 01 and program the
ACTION (A) to be "2" (Stay Closed). Press [
you want to START the Device action is a fault, so program 2 in (EV).
✱
Press [
] to continue.
To use Zone List 1 for the 3 specific zones, program 1 in (ZL), and
program these 3 zones in
2.
The second condition for turning on the indicator is triggering a 24-
hour aux. zone (Zone Type 08). Therefore, program (ZT) as 08. Press
✱
] to continue.
[
3.
To stop the Device action and turn off the lamp, you do not want to use
a restore of any zone, so enter a 0 for Stop: Zn Lst (ZL). Press [
continue.
4.
To stop the Device action and turn off the lamp, you do not want to use
a system operation or zone type, so enter a 0 for Stop: Zn Typ. (ZT).
✱
Press [
] to continue.
NOTE: A manual entry of User Code + # + 8 + Device No. (1 in this
example) is used to turn the device off. Therefore, you do not need to
program a STOP event.
5.
The system displays a summary screen for the START programming
✱
for device 01. Press [
6.
The system displays a summary screen for the STOP programming for
✱
device 01. Press [
] to continue.
7.
The system displays the X10? prompt. Enter 1 for yes.
8.
The ENTER DEVICE NO. prompt for the next zone is displayed.
✱
Press 00 and then [
✱
Now use
81 Zone List mode to program the 3 specific zones in Zone List
01.
✱
] to continue. The Event
✱
81's Zone List 1. Press [
] to continue.
✱
] to exit the
80 mode.
✱
] to continue.
✱
] to