Removing the hot-swap power supply cage

This procedure applies only to server models that have hot-swap power-supplies.
To remove the power-supply cage, complete the following steps.
1. Read the safety information that begins on page vii and "Installation guidelines"
2. Turn off the server and all attached devices; then, disconnect all power cords
3. Unlock and remove the side cover (see "Removing the side cover" on page 77).
4. Remove both hot-swap power supplies (see "Removing a hot-swap power
5. Disconnect the cables from the power-supply cage to the system board and all
6. Remove the four screws that secure the power-supply cage to the chassis;
7. If you are instructed to return the power-supply cage, follow all packaging
116
System x3200 Types 4362 and 4363: Problem Determination and Service Guide
on page 73.
and external cables.
supply" on page 98).
Note: It might be helpful to lay the server on its side for the remainder of this
procedure.
internal components.
then, slide the cage toward the front of the server to disengage the retaining
clips from the top of the chassis and lift the cage out of the chassis.
instructions, and use any packaging materials for shipping that are supplied to
you.