Error code
Description
01298101
Bad update data for processor 1.
I9990301
Hard disk drive boot sector error.
I9990650
AC power has been restored.
26
System x3200 Types 4362 and 4363: Problem Determination and Service Guide
Action
1. Update the BIOS code again (see "Updating the
firmware" on page 129).
2. (Trained service technician only) Reseat the
microprocessor.
3. (Trained service technician only) Replace the
microprocessor.
1. Reseat the following components, depending on
the server model:
v Hot-swap models:
a. Hard disk drive
b. SAS/SATA controller
v Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
2. Replace the following components one at a time,
depending on the server model, in the order
shown, restarting the server each time:
v Hot-swap models:
a. Hard disk drive
b. Hard disk drive backplane
c. SAS/SATA controller
v Simple-swap models:
a. Hard disk drive
b. Hard disk drive cable
3. (Trained service technician only) Replace the
system board.
1. Reseat the power cords.
2. Check for interruption of the external power.
3. Replace the power cords.