IBM System x3200 Problem Determination And Service Manual page 66

Hide thumbs Also See for System x3200:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, System x3200 Types 4362 and 4363," on page 67 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
035-279-001
Adapter Cache test error.
035-280-001
Adapter Drive test error.
035-281-001
Adapter Drive error.
035-282-001
Adapter Parameters set error.
035-283-001
Adapter Battery error.
035-xxx-cnn
c = ServeRAID channel number, nn = ID of
failing hard disk drive.
035-xxx-snn
Failed hard disk drive with ID nn on RAID
adapter in slot s.
035-xxx-099
No adapters were found.
035-xxx-s99
Failed RAID test: s = number of failing
adapter slot
48
System x3200 Types 4362 and 4363: Problem Determination and Service Guide
Action
1. Update the RAID controller firmware (see
"Updating the firmware" on page 129).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
Replace the attached drive.
Replace the attached drive.
1. Update the RAID controller firmware (see
"Updating the firmware" on page 129).
2. Reseat the RAID adapter.
3. Replace the RAID adapter.
Replace the battery module on the RAID adapter.
1. Check the system-event/error log and replace any
indicated failing devices.
Note: A FRU must be replaced by a trained
service technician only.
2. Reseat the hard disk drive on channel C, ID nn.
3. Replace the hard disk drive on channel C, ID nn.
1. Check the system-event/error log and replace any
indicated failing devices.
Note: A FRU must be replaced by a trained
service technician only.
2. Reseat the disk with ID nn on adapter in slot s.
3. Replace the disk with ID nn on adapter in slot s.
If an adapter is installed:
1. Reseat the adapter.
2. Check the adapter cables to be sure that they are
secure.
1. Check the system-event/error log and replace any
indicated failing devices.
Note: A FRU must be replaced by a trained
service technician only.
2. Reseat the following components:
a. RAID adapter in slot s
b. Cable for the RAID adapter in slot s
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. RAID adapter in slot s
b. Cable for the RAID adapter in slot s
c. (Trained service technician only) System
board

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents