Appliance Data And Efficiency; Appliance Data; Efficiency - Valor Brava 347 Installation And Owner's Manual

Radiant / convector gas fire
Table of Contents

Advertisement

3. APPLIANCE DATA AND EFFICIENCY

3.1 Appliance data.

Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Burner Test Pressure (Cold)
Gas Connection
Burner Injector - Upper (Centre Radiants)
Burner Injector - Lower (Outer Radiants)
Pilot & Atmosphere Sensing Device
Ignition
Aeration
The appliance information label is on the inner face of the back panel at the lower left
hand side. It is visible when the fascia is removed.

3.2 Efficiency.

The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below :
Model
347 Brava
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by BSI. The efficiency
value may be used in the UK Government's Standard Assessment Procedure (SAP)
for energy rating of dwellings.
The conversion of net efficiency to gross was achieved by multiplying the net
efficiency by the following conversion factor from Table E3 of SAP 2005, rounding
down to the nearest whole number.
Gas
Natural Gas
©
GDC Group Ltd. OCT 2016
INSTALLER GUIDE
17.95 + 0.75mbar (7.14 + 0.3in w.g.)
Conversion factor from net to gross efficiency
Page 8
Natural (G20)
20mbar
5.5 kW (18,424 Btu/h)
1.57W (5,357 Btu/h)
8mm pipe
Cat 28 - 170
Cat 28 - 170
P4 - 93
Electronic (Mounted on gas valve)
Non-adjustable
Efficiency % (Gross)
0.901
73