4. APPLIANCE DATA AND EFFICIENCY

4.1 Appliance data.

Gas
Inlet Pressure
Gross Heat Input
Burner Test Pressure (Cold)
Gas Connection
Burner Injectors
Pilot & Atmosphere Sensing Device
Ignition
Aeration
Under no circumstances is this fire to be converted to LPG. An LPG conversion kit
does not exist for this gas fire.
The appliance information label is on the inner face of the back panel at the lower left
hand side. It is visible when the fascia is removed.

4.2 Efficiency.

The efficiency of this appliance has been measured as specified in BS 7977 - 1 and
the result is as below :
Model
341
The gross calorific value of the fuel has been used for this efficiency calculation. The
test data from which it has been calculated has been certified by Advantica
Certification services (0087). The efficiency value may be used in the UK
Government's Standard Assessment Procedure (SAP) for energy rating of dwellings.
©
GDC Group Ltd. JAN 2017
INSTALLER GUIDE
Control Setting 4
Control Setting 3
Control Setting 2
Control Setting 1/IGN
Natural (G20)
5.05kW (17,200Btu/h)
3.45kW (11,800Btu/h)
1.80kW (6,100Btu/h)
1.55kW (5,300Btu/h)
17.2 + 0.75mbar (6.9 + 0.3in w.g.)
Upper - Bray Cat. 99 Size 115
Lower - Bray Cat. 99 Size 230A
SIT Ref. OPNG9419
Piezo-electric integral with gas tap
Non-adjustable
Page 8
20mbar
8mm pipe
Efficiency % (Gross)
79