Accessory List; Appliance Data And Efficiency; General Information - Valor 474 Valentia Installation And Owner's Manual

Balanced flue room sealed radiant / convector gas fire
Table of Contents

Advertisement

Note that in England and Wales the Building Regulations require a terminal guard to
be fitted if the terminal is less than 2m (6ft 6in) from the level of any ground, balcony,
flat roof or place to which any person has access and which adjoins the wall in which
the outlet is situated. A suitable guard assembly is available. Part No. 994371.
In Scotland, although the Building Standards (Scotland) do not require a terminal
guard to be fitted, the fitting of a guard as detailed above is recommended.
- Combustible wall kit, Part no. 994530 is available as an optional extra.
Four telescopic flues are available:
- Min Flue (Telescopic) for walls from
- Short flue for walls from
- Medium flue for walls from
- Long flue for walls from
NOTE: The fire is supplied with Medium flue only. Short & Long flues are optional extras.

3. APPLIANCE DATA AND EFFICIENCY

3.1 General information.

Gas
Inlet Pressure
Input - Max. (Gross)
Input - Min. (Gross)
Pressure Setting (Cold)
Height to Centre Line of Flue
Burner Injector Upper
Burner Injector Lower
Main Burner:
Ignition:
Flame Control:
Spark Gap:
Pilot Unit:
The appliance information label is at the left side of the rear case and is visible after
removing the fascia. In addition, for customers reference, there is a label giving the
appliance serial number on the outside of the fascia at the bottom right side.
©
GDC Group Ltd. 2014
INSTALLER GUIDE

2. ACCESSORY LIST

150mm to 203mm
75mm to 203mm
200mm to 356mm
356mm to 510mm
Page 8
Natural (G20)
20mbar (8in w.g.)
4.5kW
1.5kW
17.5 +/- 1.0mbar
351mm
Cat. 77/180
Cat. 77/160
Aerated Duplex
Battery spark generator
Part No. 987623
3 to 4mm
SIT 0150060, SIT No.34
No. 990177
No. 993241
No. 993240
No. 993239