TRENDnet User's Guide
New Password : Enter a new password if desired
o
Check New Password: Enter the same new password again to check.
o
Admin Login Methods:
Enable HTTP: Check to select HTTP Service.
o
HTTP Port: The default is 80 and the range is between 1 ~ 65535.
o
Enable HTTPS: Check to select HTTPS Service
o
HTTPS Port: The default is 443 and the range is between 1 ~ 65535.
o
Enable Telnet: Check to select Telnet Service
o
Telnet Port: The default is 23 and the range is between 1 ~ 65535.
o
Enable SSH: Check to select SSH Service
o
SSH Port: The default is 22 and the range is between 1 ~ 65535.
o
Ping Watchdog: The ping watchdog sets the TEW-738APBO Device to continuously
ping a user defined IP address (it can be the internet gateway for example). If it is
unable to ping under the user defined constraints, the TEW-738APBO device will
automatically reboot. This option creates a kind of "fail-proof" mechanism.
Ping Watchdog is dedicated for continuous monitoring of the particular connection
to remote host using the Ping tool. The Ping works by sending ICMP "echo request"
packets to the target host and listening for ICMP "echo response" replies. If the
defined number of replies is not received, the tool reboots the device.
© Copyright 2014TRENDnet. All Rights Reserved.
Enable Ping Watchdog: control will enable Ping Watchdog Tool.
o
IP Address To Ping: specify an IP address of the target host which will be
o
monitored by Ping Watchdog Tool.
Ping Interval: specify time interval (in seconds) between the ICMP "echo
o
requests" are sent by the Ping Watchdog Tool. Default is 300 seconds.
Startup Delay: specify initial time delay (in seconds) until first ICMP "echo
o
requests" are sent by the Ping Watchdog Tool. The value of Startup Delay should
be at least 60 seconds as the network interface and wireless connection
initialization takes considerable amount of time if the device is rebooted. Default
is 300 seconds.
Failure Count To Reboot: specify the number of ICMP "echo response" replies. If
o
the specified number of ICMP "echo response" packets is not received
continuously, the Ping Watchdog Tool will reboot the device.
Click Save button to save your changes. Click Reboot button to activate your changes
Without a valid certificate, users may encounter the following problem in IE7 when they
try to access system's WMI (https://192.168.2.254). There will be a "Certificate Error",
because the browser treats system as an illegal website.