Serial 1 Wrap
The Serial 1 Wrap Test is used to check the operation of the serial port hardware using a wrap plug. Each serial
signal is tested.
To perform the Serial 1 Wrap Test:
Disconnect the serial interface cable, and install the serial wrap plug.
1.
Select HARDWARE TESTS from the Diagnostics Menu, and press Select (
2.
Select Serial 1 Wrap, and press Select (
3.
The power indicator blinks indicating the test is in progress. The following screens appear
Serial Wrap [x] Testing...
Resetting the
Printer
Upon completion of the POR, the following screen is displayed:
Serial Wrap
P:######
F:####
P:###### represents the number of times the serial port hardware has passed.
Initially, 000000 is displayed. The maximum pass count is 999,999.
F:###### represents the number of times the serial port hardware has failed.
Initially, 0000 is displayed. The maximum fall count is 999,999.
Any of the following explanations for failure may display:
Receive Status Interrupt Error
Status Error
Receive Data Interrupt Error
Transmit Data Interrupt Error
Transmit Empty Error
Threshold Error
Receive Data Ready Error
Break Interrupt Error
Framing Error
Parity Error
Overrun Error
Data Error
Data 232 Error
Data 422 Error
FIFO Error
DSR Error
DSR PIO Error
DSR Interrupt Error
CTS Error
CTS PIO Error
CTS Interrupt Error
).
5026
).