Models 330S and 660S
HP Series 6000
Reinstalling the BEND/flex Cable
To reinstall the BEND /tlex cable, perform the steps in
"Removing the BEND /tlex Cable" in reverse order.
Connecting the Cables to the Rewritable Optical Controller PCA
Connect the cables to the rewritable optical controller PCA
as follows (see Figure 3-12):
1. Connect the BEND /tlex cable adapter
to the BEND/flex
cable.
2. Connect the other end of the BEND/flex cable adapter to
the SCSI connector on the rewritable optical controller
PCA.
3. Connect the control cable to the control connector on the
rewritable optical controller PCA.
4. Connect the data cable to the data connector on the
rewritable optical controller PCA.
5. Connect one of the split ends of the dc power cable
to the dc power connector on the rewritable optical
controller PCA.
6. Connect the long end (with the 14-pin connector) of the
dc power cable to any of the unused dc power connectors
on the power supply (see Figure 3-13).
3·38
Rewritable Optical Disk Drive