Ambient Temperature Sensor - Malaguti Password 250 i.e. Workshop Manual

Frame and running gear
Table of Contents

Advertisement

FRAME AND RUNNING GEAR
A
5

AMBIENT TEMPERATURE SENSOR

• (Remove windshield).
• (Remove upper handlebar cover).
• Detach connector (A).
• Remove sensor (B) from lower handlebar cover (C).
The sensor must be mounted EXTERNAL-
LY to the lower handlebar cover as shown
in the figure.
RIGHT-HAND CONTROL
• (Remove windshield).
• (Remove upper handlebar cover).
• Disconnect throttle transmission (A).
• Undo screw (V) and remove counterweight.
• Undo screws (V2) and remove throttle control.
Use compressed air to reduce friction when
removing and refitting the twist grip.
D I S A S S E M B LY
52
A
C
V
11/06
PASSWORD 250 i.e.
B
V
2
A